General Programming Using The System Keypad; Relay Strike Time; Talk Time - DoorKing 1835 Owner's Manual

Pc programmable telephone entry and access control systems
Table of Contents

Advertisement

3.3 General Programming Using the System Keypad

Proceed with the programming steps on the following pages ONLY IF PC programming WILL NOT be
used. The system keypad may be used to program some features on the telephone entry system but can
be a little tedious to use. We strongly suggest that you become familiar with the programming steps in
A
SP
SP
ABC
ABC
DEF
DEF
1 1
2 2
3 3
each feature you want to use BEFORE actually programming the system.
GHI
GHI
JKL
JKL
MNO
MNO
Z
4 4
5 5
6 6
PQRS
PQRS
TUV
TUV
WXYZ
WXYZ
7 7
8 8
9 9
OPER
OPER
0 0
CALL
System Keypad

3.3.1 Relay Strike Time

These steps will program Relay 0, Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4 second up to 99
seconds by entering the desired time in seconds as a two-digit number in step 3. If Expansion boards are going to be used with
this system, set Relay 2 strike time to 00 for Expansion boards 1-8. If more than 8 Expansion boards are being used, set Relay
1 strike time to 00 (for Expansion boards 9-16) and then set Relay 0 strike time for the desired time in seconds. In this applica-
tion, Relay 0 becomes the PRIMARY relay that will open the door or gate after the resident presses 9 on their telephone.
Factory setting for relay strike times are: Relay 0 = 01 (1 sec), Relay 1 = 01 (1 sec), Relay 2 = 01 (1 sec).
OPER
OPER
DEF
DEF
1. Press
and enter your four-digit MASTER CODE
0 0
3 3
OPER
OPER
2. Press
(beep) to set Relay 0, OR
0 0
3. Enter the two-digit strike time in seconds (00-99), then press
(Example: 1/4 second - enter 00, 1 second - enter 01 etc.)
4. Repeat steps 2 and 3 to set other relay strike times.
OPER
OPER
5. Press
together to end this programming sequence (beeeeeep).
0 0

3.3.2 Talk Time

This programming sequence sets the maximum time allowed for conversation when the entry system places a call to the
resident. The talk time can be set from 1 second up to 255 seconds (4 minutes, 15 seconds) and is entered as a three-digit
number in step 3. The talk time set here DOES NOT affect the telephone numbers that are programmed under directory codes 0,
00, 000, 0000 and 1, 01, 001, 0001. The talk time for these two directory code sets are factory set to the maximum. Phone
numbers programmed under these directory codes should be reserved for management or emergency phone numbers that
generally require longer conversations.
Factory setting for talk time = 060 (60 seconds).
OPER
OPER
TUV
TUV
1. Press
and enter your four-digit MASTER CODE
0 0
8 8
2. Enter the three-digit talk time in seconds (001-255), then press
(Example: 1 second - enter 001, 20 seconds - enter 020 etc.)
OPER
OPER
3. Press
together to end this programming sequence (beeeeeep).
0 0
34
Important Note:
If you make a mistake while programming, press
to escape from programming no matter how much has been completed, then begin again at step 1.
SP
SP
1 1
? ?
? ?
? ?
? ?
(beep) to set Relay 1, OR
(beep).
? ?
? ?
? ?
? ?
(beep).
OPER
OPER
keys at the same time
0 0
(beep).
ABC
ABC
(beep) to set Relay 2 strike time.
2 2
(beep).
1835-065-D-5-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents