Fitting the mounting bracket (individually)

Safety

Danger from incorrect operation and work that is not carried out properly.
This can result in serious personal injury and damage to property.
Fitting the
IMPORTANT!
mounting bra-
-
cket (individual-
ly)
-
1
3
WARNING!
All the work and functions described in this document must only be carried
out by technically trained and qualified personnel.
Read and understand this document in full.
Read and understand all safety rules and user documentation for this device
and all system components.
Drill a Ø5.8 mm hole for the mounting bracket and use a reamer to enlarge
the hole so it can accommodate the dowel pin (Ø6G7).
The mounting bracket must be fitted using an M8 shoulder screw.
The required bracket must then be positioned and two dowel pins (Ø6 mm)
driven in to secure it.
2
2
1
Drill
1
Ø5,8
6
Reamer
Ø6G7