The Program Is Not Interrupted, But Faults Are Logged Into The Fault Memory - Miele G2000 Technical Information

Hide thumbs Also See for G2000:
Table of Contents

Advertisement

Technical Information
Case 2: If the fault is registered later, the fault will be indicated in the
1. The cause may lie with the position switch B3/12, which may have an
intermittent contact. Check for dirty contacts clean or replace drive as necessary.
2. Check for pulses during operation at ST14 on the electronic board using a multi-
meter set for low voltage DC. If you are receiving pulses every 30 sec. then
replace the electronic board if you are receiving no pulses, replace the drive.
6.8.16
The program is not interrupted, but faults are logged into the fault
memory.
If the following faults are registered, the program is not interrupted. The fault will only
be indicated when the fault memory is checked in the service mode.
A water intake fault: hot water is registered (F15)
During the energy saving program if the water temperature is below 100°F an F15
fault is logged into memory. The on-site water supply should be checked by a
specialist.
A Speed Sensor Fault is registered (F53)
The circulation pump continues to operate but is not monitored.
1. Check for popper operation of the circulation pump, see F14 par. 1e. Clean and
remove any blockage that may be present.
2. The speed sensor B3/9 may be defective. Replace speed sensor.
A Slide shutter fault is registered (F63)
Even though the slide shutter motor has been activated, there is no signal change at
the position switch. The slide shutter motor will be activated again whenever
repositioning is required.
1. Check to see if water is alternating between the upper/lower spray arms and the
middle spray arm. This can be done by removing the side panels, selecting a
wash program and observing the water flow between the upper spray arm and
middle spray arm water paths. If the water flow is alternating go to section "a"
below. If not go to section "b" below.
2. Check the position switch B3/12 at connection ST14 (using a multi-meter) for low
DC pluses at 30 sec. intervals.
display or via LEDs at the end of the program. The buzzer is then
activated for 2 min.
G1000 / G2000 Dishwashers
220

Advertisement

Table of Contents
loading

Table of Contents