1.
Open the door.
2.
Remove the bottom basket.
3.
Remove the bottom spray arm.
4.
Remove the filter combination.
5.
Remove as much residual water as possible from the sump and drain hose.
6.
Lay the dishwasher on its back.
7.
Remove Drip pan, 5.1.2
8.
Disconnect the NTC temperature sensor plug connections.
9.
Remove the NTC temperature sensor.
10. Remove the sealing ring.
5.4.20

Filter Combination Dismantling

Note
During reassembly, a locking piece must be fitted to prevent the filter
combination from falling apart, see Filter combination assembly (with
locking piece) (5.4.22).
As an alternative, the micro fine filter and the handle piece (crown
coarse filter) must be exchanged together, see Filter combination
assembly (new micro fine filter and handle) (5.4.21).
1. Open the filter cap.
Figure 5-34: Combination Filter
Note
If the filter combination is already held together with a locking piece, this
must be broken open and removed.