Miele G2000 Technical Information page 164

Hide thumbs Also See for G2000:
Table of Contents

Advertisement

Technical Information
Flashing
Rhythm of
Function
Gel LED
Long Short
Pos 4:
Buzzer
on/off
-
4
Long Short
Pos. 5:
Sensor
wash
program
modification
(from
software
version ID
No. 984)
-
5
Long Short
Pos. 12:
Resetting
standard
settings *2
1
2
Table 6-39: G1470 / G2470 Programming Mode Options (Cont. from Table 6-38) (Cont. on Table 6-40)
Programming
Press the Gel
The display shows
button 4 times. The
P and a digit
Gel LED flashes 4
alternately: P0 =
times rapidly
Buzzer off; P1 =
intermittently. Press
Buzzer on.
the program button
as appropriate to
make the desired
setting.
Press the Gel
The display shows
button 5 times. The
P and a digit
Gel LED flashes 5
alternately: P0 =
times rapidly
Normal program
intermittently. Press
sequence (standard
the program button
setting); P1 =
as appropriate to
Modified program
make the desired
sequence. This is
setting.
used to adjust the
Sensor wash
program
parameters so it
can be used to
wash items with
stubborn stains
even if the overall
level of soiling is
otherwise low.
Press the Gel
The display shows
button 12 times.
P and a digit
The Gel LED
alternately: P0 =
flashes once slowly
Normal program
and 2 times rapidly
sequence (standard
intermittently. Press
setting); P1 =
the program button
Modified program
to reset all standard
sequence. This is
settings.
used to adjust the
Sensor wash
program
parameters so it
can be used to
wash items with
stubborn stains
even if the overall
level of soiling is
otherwise low.
164
G1000 / G2000 Dishwashers
Flashing Rhythm of
Display
Sani-Wash LED
Long Short Display
-
-
Long Short Display
-
-
Long
-
-
-
P0
1
P1
-
P0
1
P1
Short
Display
-
P0
1
P1