Miele G2000 Technical Information page 135

Hide thumbs Also See for G2000:
Table of Contents

Advertisement

G1000 / G2000 Dishwashers
Flashing
Rhythm of
Function
Intake/Drain
Lt.
Pos. 0:
Long Short
Software
version ID
-
-
check
Pos. 1:
Long Short
Fault
memory
display and
deletion
-
1
Table 6-21: G2140 Service Mode Options (Continued on Table 6-22).
Programming
Do not press the
The Rinse LED is
Program button.
off. Shows the
The Rinse & Hold
software version ID
LED is off.
No., e.g. -769
Press the Program
The Rinse LED is
button once. The
off or flashes to
Rinse & Hold LED
show the fault code
flashes once rapidly
number alternately
intermittently. Press
see 6.7, Fault code
the Start/Stop
summary. If the
button.
fault memory is
Press it again to
empty, the Rinse
display fault codes
LED is off.
that may have been
saved. To delete
the fault memory,
press the Start/Stop
button again and
hold it for 4 sec.
135
Flashing Rhythm of
Display
Rinse LED
Long Short Display
-
Long Short Display
-
-
-
1
1
1
1
1
1
2
2
2
4
5
6
7
8
Technical Information
-
-
-
F0
1
F1
2
F2
1
F11
2
F12
3
F13
4
F14
8
F18
9
F19
4
F24
5
F25
6
F26
-
F40
1
F51
9
F69
-
F70
8
F88

Advertisement