G1000 / G2000 Dishwashers
Figure 5-20: Connecting Strip Removal
Note
Use care when removing the connecting strip as the electrical connector
to the waterproof inlet valves are held in place by retainers mounted on
the inside of the connecting strip.
5.3.5

Multi-Plinth Removal (Door Tension Spring Housing)

1. Side panel removal (5.1.1).
2. Connecting strip removal (5.3.4).
Figure 5-21: Connecting Strip
3. Remove the connecting strip retaining screws, Fig. 5-21, Item 1.
4. Release the cord from the spring.
5. Pull out the multi-plinth from the guide integrated in the rear panel.
Note
Take care removing the left plinth. The electrical connector to the waterproof
inlet valves is held in place. To remove, release retaining clips.