ADF Web HD67507-Slim-232 User Manual

ADF Web HD67507-Slim-232 User Manual

Modbus tcp slave / modbus master - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 2.400
English
Modbus TCP Slave / Modbus Master - Converter
(Order Code: HD67507-A1, HD67507-A1-422, HD67507-B2,
HD67507-Slim-232, HD67507-Slim-485, HD67507-WiFi-B2-
232, HD67507-WiFi-B2-485)
for Website information:
www.adfweb.com?Product=HD67507
for Price information:
www.adfweb.com?Price=HD67507-A1
www.adfweb.com?Price=HD67507-A1-422
www.adfweb.com?Price=HD67507-B2
www.adfweb.com?Price=HD67507-Slim-232
www.adfweb.com?Price=HD67507-Slim-485
www.adfweb.com?Price=HD67507-WiFi-B2-232
www.adfweb.com?Price=HD67507-WiFi-B2-485
Benefits and Main Features:
Wide supply input range
Galvanic Isolation
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual Modbus TCP Slave / Modbus Master
Document code: MN67507_ENG
For others products, see also the following links:
RS232 / RS485 / USB / Ethernet
www.adfweb.com?Product=HD67118
www.adfweb.com?Product=HD67119
www.adfweb.com?Product=HD67038
CAN / CANopen / Modbus / Modbus TCP
www.adfweb.com?Product=HD67001
www.adfweb.com?Product=HD67502
www.adfweb.com?Product=HD67011
www.adfweb.com?Product=HD67012
www.adfweb.com?Product=HD67514
www.adfweb.com?Product=HD67515
Modbus RTU Slave / Modbus TCP Master - Converter
www.adfweb.com?Product=HD67510
Do you have your customer protocol? Then go to:
www.adfweb.com?Product=HD67003
Do you need to choose a device? Do you want help?
www.adfweb.com?Cmd=helpme
Revision 2.400
Page 1 of 45
(RS232 / RS485 - Converter)
(USB / RS485 - Converter)
(RS485 / RS232 / Ethernet - Converter)
(CANopen / Modbus Master - Converter)
(CANopen / Modbus Slave - Converter)
(CAN / Modbus Master - Converter)
(CAN / Modbus Slave - Converter)
(CAN / Modbus TCP Master – Converter)
(CAN / Modbus TCP Slave – Converter)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67507-Slim-232 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD67507-Slim-232

  • Page 1 Page 1 of 45 Industrial Electronic Devices User Manual Revision 2.400 English Modbus TCP Slave / Modbus Master - Converter (Order Code: HD67507-A1, HD67507-A1-422, HD67507-B2, HD67507-Slim-232, HD67507-Slim-485, HD67507-WiFi-B2- 232, HD67507-WiFi-B2-485) for Website information: www.adfweb.com?Product=HD67507 for Price information: www.adfweb.com?Price=HD67507-A1 www.adfweb.com?Price=HD67507-A1-422 For others products, see also the following links: www.adfweb.com?Price=HD67507-B2...
  • Page 2: Updated Documentation

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 2 of 45 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that you Page need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 3 of 45 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation.
  • Page 4: Examples Of Connection

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 4 of 45 Industrial Electronic Devices EXAMPLES OF CONNECTION: ADFweb.com S.r.l.
  • Page 5 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 5 of 45 Industrial Electronic Devices ADFweb.com S.r.l.
  • Page 6: Connection Scheme

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 6 of 45 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67507-A1 ADFweb.com S.r.l.
  • Page 7 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 7 of 45 Industrial Electronic Devices Figure 1b: Connection scheme for HD67507-A1-422 ADFweb.com S.r.l.
  • Page 8 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 8 of 45 Industrial Electronic Devices Figure 1c: Connection scheme for HD67507-B2 ADFweb.com S.r.l.
  • Page 9 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 9 of 45 Industrial Electronic Devices Figure 1d: Connection scheme for HD67507-Slim-232 ADFweb.com S.r.l.
  • Page 10 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 10 of 45 Industrial Electronic Devices Figure 1e: Connection scheme for HD67507-Slim-485 ADFweb.com S.r.l.
  • Page 11 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 11 of 45 Industrial Electronic Devices Figure 1f: Connection scheme for HD67507-WiFi-B2-232 ADFweb.com S.r.l.
  • Page 12 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 12 of 45 Industrial Electronic Devices Figure 1g: Connection scheme for HD67507-WiFi-B2-485 ADFweb.com S.r.l.
  • Page 13 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 13 of 45 Industrial Electronic Devices CHARACTERISTICS: The HD67507 is a Modbus TCP Slave / Modbus Master – Converter. It allows for the following characteristics: Triple isolation between Serial - Power Supply, Serial - Ethernet, Power Supply - Ethernet. Ethernet 10Base-T / 100Base-T, autosensing for Modbus TCP;...
  • Page 14: Power Supply

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 14 of 45 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin...
  • Page 15: Function Modes

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 15 of 45 Industrial Electronic Devices FUNCTION MODES: The device has got two function modes depending on the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 16 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 16 of 45 Industrial Electronic Devices LEDS (for HD67507-A1 and HD67507-B2): The devices has got four (five for HD67507-B2) LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below.
  • Page 17 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 17 of 45 Industrial Electronic Devices LEDS (for HD67507-Slim-xxx): The devices has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 18 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 18 of 45 Industrial Electronic Devices LEDS (for HD67507-WiFi-B2): The devices has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 19 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 19 of 45 Industrial Electronic Devices ETHERNET: The Ethernet connection must be made using Connector2/3/5 of HD67507 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 20 The HD67507-A1/B2 is provided with a D-sub connector type DE-9 Male (also called DB-9). The cable must use a DE-9 Female connector. The serial port is used for programming the device and for Modbus communication. The HD67507-Slim-232 and HD67507-WiFi-B2-232 is provided with a 3way 5mm removable screw terminal. The serial port is used for Modbus communication.
  • Page 21 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 21 of 45 Industrial Electronic Devices RS485: To terminate the RS485 line with a 120Ω resistor, it is necessary to put dip 1 ON, like in figure. ADFweb.com S.r.l.
  • Page 22 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 22 of 45 Industrial Electronic Devices The maximum length of the cable should be 1200m (4000 feet). Here some codes of cables: Belden: p/n 8132 - 2x 28AWG stranded twisted pairs conductor + foil shield + braid shield; Belden p/n 82842 - 2x 24AWG stranded twisted pairs conductor + foil shield + braid shield;...
  • Page 23 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 23 of 45 Industrial Electronic Devices USE OF COMPOSITOR SW67507: To configure the Converter, use the available software that runs with Windows called SW67507. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 24: New Configuration / Open Configuration

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 24 of 45 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “Modbus TCP Slave / Modbus Master - Converter”...
  • Page 25: Software Options

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 25 of 45 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 26: Set Communication

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 26 of 45 Industrial Electronic Devices SET COMMUNICATION: By Pressing the “Set Communication” button from the main window for SW67507 (Fig. 2) the window “Set Communication” appears (Fig. 3). The window is divided in different sections in order to define the different parameters of the converter: Select Device...
  • Page 27: Select Device

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 27 of 45 Industrial Electronic Devices ELECT EVICE In the section “Select Device” it is possible to select the type of converter used: HD67507 (Modbus TCP on Ethernet); Figure 3b: “Set Communication ...
  • Page 28: Operation Mode

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 28 of 45 Industrial Electronic Devices PERATION In the section “Operation Mode” it is possible to define the working mode of the converter (see page 33 for more info): Routing Mode;...
  • Page 29: Modbus Tcp Slave

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 29 of 45 Industrial Electronic Devices TCP S ODBUS LAVE This section is used to define the general parameters of Modbus TCP. The means of the fields are: In the field “IP Address”...
  • Page 30: Dhcp Subnet

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 30 of 45 Industrial Electronic Devices This section is used to define the general parameters of Wi-Fi. It is possible to defined the type of Wi-Fi communication: Access Point;...
  • Page 31 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 31 of 45 Industrial Electronic Devices The means of the fields for Client configuration are: If the field “Obtain an IP Address automatically” is checked, the converter gets the IP Address using DHCP.
  • Page 32 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 32 of 45 Industrial Electronic Devices The means of the fields for “Modbus TCP Slave on Wi-Fi” for Client configuration are: If the field “Obtain an IP Address automatically”...
  • Page 33 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 33 of 45 Industrial Electronic Devices OPERATION MODE: OUTING A few characteristics of the Modbus RTU package have been modified in the standard of the Modbus TCP protocol. Two bytes of the final CRC were eliminated (no longer necessary for the information to reach its already corrected destination).
  • Page 34: Translate Table

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 34 of 45 Industrial Electronic Devices TRANSLATE TABLE: Within the section “Translate Table” it is possible to define the variables that can be read or written by the TCP bus on the RTU bus when the device is in NAT mode.
  • Page 35 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 35 of 45 Industrial Electronic Devices Example 1: If you want, from TCP network, write a data it the RTU network on the device at: Address 5; Through Gateway WORD 100 (Address RTU);...
  • Page 36: Update Device

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 36 of 45 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. If you don’t know the actual IP address of the device you have to use this procedure: Turn OFF the Device;...
  • Page 37 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 37 of 45 Industrial Electronic Devices Note: When you install a new version of the software, if it is the first time it is better you do the update of the Firmware in the HD67507 device.
  • Page 38: Mechanical Dimensions

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 38 of 45 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 7a: Mechanical dimensions scheme for HD67507-A1 Figure 7b: Mechanical dimensions scheme for HD67507-A1-422 ADFweb.com S.r.l.
  • Page 39 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 39 of 45 Industrial Electronic Devices Figure 7c: Mechanical dimensions scheme for HD67507-B2 ADFweb.com S.r.l.
  • Page 40 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 40 of 45 Industrial Electronic Devices Figure 7d: Mechanical dimensions scheme for HD67507-WiFi-B2-xxx ADFweb.com S.r.l.
  • Page 41 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 41 of 45 Industrial Electronic Devices Figure 7e: Mechanical dimensions scheme for HD67507-Slim-xxx ADFweb.com S.r.l.
  • Page 42: Ordering Informations

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 42 of 45 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67507 - xxxx – xx - xxx Serial port: None: RS232 + RS485 (only for HD67507-A1 and HD67507-B2) 232: RS232 (only for HD67507-WiFi-B2-xxx and HD67507-Slim-xxx)
  • Page 43 Order Code: HD67507-B2 Modbus TCP Slave / Modbus Master – Converter ( Modbus TCP: Ethernet - Modbus RTU: RS232 or RS485 ) Order Code: HD67507-Slim-232 Modbus TCP Slave / Modbus Master – Converter ( Modbus TCP: Ethernet - Modbus RTU: RS232 ) Order Code: HD67507-Slim-485 Modbus TCP Slave / Modbus Master –...
  • Page 44 User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 44 of 45 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 45: Warranties And Technical Support

    User Manual Modbus TCP Slave / Modbus Master Document code: MN67507_ENG Revision 2.400 Page 45 of 45 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents