Download Print this page

ADF Web HD67506-A1 User Manual

Modbus master / ethernet - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.100
English
Modbus Master / Ethernet - Converter
(Order Code: HD67506-A1, HD67506-B2)
for Website information:
www.adfweb.com?Product=HD67506
for Price information:
www.adfweb.com?Price=HD67506-A1
www.adfweb.com?Price=HD67506-B2
Benefits and Main Features:
Very easy to configure
Low cost
32mm Rail DIN mount
Wide supply input range
Galvanic Isolation of RS485
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
User Manual Modbus Master / Ethernet
Document code: MN67506_ENG
HD67506-A1
For others products, see also the following links:
RS232 / RS485 / USB / Ethernet
www.adfweb.com?Product=HD67118
www.adfweb.com?Product=HD67119
www.adfweb.com?Product=HD67038
CAN / CANopen / Modbus / Modbus TCP
www.adfweb.com?Product=HD67001
www.adfweb.com?Product=HD67502
www.adfweb.com?Product=HD67011
www.adfweb.com?Product=HD67012
www.adfweb.com?Product=HD67514
www.adfweb.com?Product=HD67515
Modbus RTU Slave / Modbus TCP Master - Converter
www.adfweb.com?Product=HD67510
Do you have your customer protocol? Then go to:
www.adfweb.com?Product=HD67003
Do you need to choose a device? Do you want help?
www.adfweb.com?Cmd=helpme
in India
in India
in India
in India
Revision 1.100
Page 1 of 30
HD67506-B2
(RS232 / RS485 - Converter)
(USB / RS485 - Converter)
(RS485 / RS232 / Ethernet - Converter)
(CANopen / Modbus Master - Converter)
(CANopen / Modbus Slave - Converter)
(CAN / Modbus Master - Converter)
(CAN / Modbus Slave - Converter)
(CAN / Modbus TCP Master – Converter)
(CAN / Modbus TCP Slave – Converter)

Advertisement

loading
Need help?

Need help?

Do you have a question about the HD67506-A1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD67506-A1

  • Page 1 Document code: MN67506_ENG Revision 1.100 Page 1 of 30 Industrial Electronic Devices User Manual Revision 1.100 English Modbus Master / Ethernet - Converter (Order Code: HD67506-A1, HD67506-B2) for Website information: HD67506-B2 www.adfweb.com?Product=HD67506 HD67506-A1 for Price information: www.adfweb.com?Price=HD67506-A1 www.adfweb.com?Price=HD67506-B2 For others products, see also the following links:...
  • Page 2 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 2 of 30 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 3 of 30 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 4 of 30 Industrial Electronic Devices EXAMPLES OF CONNECTION: ADFweb.com S.r.l.
  • Page 5 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 5 of 30 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67506-A1 ADFweb.com S.r.l.
  • Page 6 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 6 of 30 Industrial Electronic Devices Figure 1b: Connection scheme for HD67506-B2 ADFweb.com S.r.l.
  • Page 7 Page 7 of 30 Industrial Electronic Devices CHARACTERISTICS: The HD67506-A1 and HD67506-B2 are a Modbus Master / Ethernet – Converter. It allows for the following characteristics: Triple isolation between Serial - Power Supply, Serial - Ethernet, Power Supply - Ethernet.
  • Page 8 The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC: Device Consumption [W/VA] HD67506-A1 HD67506-B2 Caution: Not reverse the polarity power HD67506-A1 HD67506-B2 ADFweb.com S.r.l.
  • Page 9 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 9 of 30 Industrial Electronic Devices FUNCTION MODES: The device has got two function modes depending on the position of the ‘Dip2 of Dip-Switch A’: The first, with ‘Dip2 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip2 of Dip-Switch A’...
  • Page 10 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 10 of 30 Industrial Electronic Devices LEDS: The devices has got four (five for HD67506-B2) LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 11 ETHERNET: The Ethernet connection must be made using Connector5 of HD67506-A1/HD67506-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to a Hub/Switch the use of a straight cable is recommended.
  • Page 12 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 12 of 30 Industrial Electronic Devices RS485: To terminate the RS485 line with a 220Ω resistor, it is necessary to put dip 1 ON, like in figure. The maximum length of the cable should be 1200m (4000 feet). Here some codes of cables: Belden: p/n 8132 - 2x 28AWG stranded twisted pairs conductor + foil shield + braid shield;...
  • Page 13 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 13 of 30 Industrial Electronic Devices USE OF COMPOSITOR SW67506: To configure the Converter, use the available software that runs with Windows called SW67506. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 14 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 14 of 30 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “Modbus Master / Ethernet - Converter”...
  • Page 15 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 15 of 30 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 16 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 16 of 30 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, Modbus and Ethernet. By Pressing the “Set Communication” button from the main window for SW67506 (Fig. 2) the window “Set Communication”...
  • Page 17 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 17 of 30 Industrial Electronic Devices SET MODBUS ACCESS: By Pressing the “Set Modbus Access ” button from the main window of SW67506 (Fig. 2), the window “Set Modbus Access” appears (Fig. 4) (only if “Device from May 2014 (with Dip-Switch)”...
  • Page 18 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 18 of 30 Industrial Electronic Devices The means of the fields in the window (Write) are the follows: In the field “Slave ID” the address of the Modbus device that you have to write is defined; In the field “Type”...
  • Page 19 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 19 of 30 Industrial Electronic Devices UPDATE DEVICE (VIA SERIAL): By pressing the “Update Device” button (if “Device till April 2014 (with Jumper)” is used) it is possible to load the created Configuration into the device, and also the Firmware if is necessary, using the RS232 port.
  • Page 20 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 20 of 30 Industrial Electronic Devices UPDATE DEVICE (VIA ETHERNET): By pressing the “Update Device” button (if “Device from May 2014 (with Dip-Switch)” is used), it is possible to load the created Configuration into the device;...
  • Page 21 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 21 of 30 Industrial Electronic Devices If you know the actual IP address of the device, you have to use this procedure: Turn on the Device with the Ethernet cable inserted; Insert the actual IP of the Converter;...
  • Page 22 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 22 of 30 Industrial Electronic Devices ETHERNET PROTOCOL: This protocol is able to read and write frames in the Modbus net. This protocol is very simple; you must known only the “Type of Data”, the “Device Address”...
  • Page 23 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 23 of 30 Industrial Electronic Devices The Bytes that composed the respons are these: Byte Number Description Status of operation The “Status of operation” (Byte Number 1) can have these values: 0xFF: Ok;...
  • Page 24 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 24 of 30 Industrial Electronic Devices RAMES The transmission has a fixed structure that consist of seven byte. Byte Number Description Read Identifier (Read=0x01) Type of Data Device Address Start Address Hi Start Address Lo Number of Point Hi...
  • Page 25 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 25 of 30 Industrial Electronic Devices (“S ” RITE THERNET ARRAY ODBUS CCESS TABLE ONLY FOR ARDWARE ERSION WITH WITCHES The transmission has a fixed structure that consist of seven bytes plus the data. Byte Number Description Command Identifier (0x03)
  • Page 26 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 26 of 30 Industrial Electronic Devices The response includes the following byte: Byte Number Description Write Error Byte Read Error Byte 3÷n+2 Data Read n=Number of Byte to Read The Error bytes (Byte 1/Byte 2) can have three values: •...
  • Page 27 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 27 of 30 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 8: Mechanical dimensions scheme for HD67506-A1 Figure 9: Mechanical dimensions scheme for HD67506-B2 ADFweb.com S.r.l.
  • Page 28 B: 4M, 35mm DIN Rail mounting Device Family HD67506: Modbus Master / Ethernet - Converter Order Code: HD67506-A1 Modbus Master / Ethernet - Converter ( Housing type: A, Terminal Blocks Connectors ) Order Code: HD67506-B2 Modbus Master / Ethernet - Converter ( Housing type: B, Terminal Blocks Connectors )
  • Page 29 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 29 of 30 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 30 User Manual Modbus Master / Ethernet Document code: MN67506_ENG Revision 1.100 Page 30 of 30 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.