W
-F
:
I
I
This section is used to define the general parameters of Wi-Fi. It is possible to defined the type of Wi-Fi communication:
Access Point;
Client.
The means of the fields for Access Point configuration are:
In the field
"IP
Address" the IP address of the converter is defined;
In the field
"Subnet
Mask" the SubNet Mask of the converter is defined;
In the field "GATEWAY" the default gateway of the net is defined. This
feature can be enabled or disabled pressing the Check Box field. This feature
is used for going out of the net;
In the field "SSID" the name of the Wi-Fi network to create is defined;
In the field "Password" the password used for Wi-Fi connection is defined;
In the field "Type" the type of security protocol used by the Wi-Fi network is
defined;
If the field
"Enable
DHCP" is checked, the converter acts as DHCP Server
for the Clients connected. If the option is enabled, in the fields
IP
Address" and

"DHCP SUBNET

DHCP is defined. In the field
the renewing of the IP Address assigned to the Client is defined;
In the field
"Max
Client" the maximum number of Wi-Fi Clients accepted is defined;
In the field "Channel" the channel for Wi-Fi communication is defined.
ADFweb.com S.r.l.
Mask" the IP Addresses range used for
"Lease Time
(seconds)" the required time for
User Manual Modbus TCP Slave / Modbus Master
Document code: MN67507_ENG
"DHCP First
Figure 3f: "Set Communication
Revision 2.400
Page 30 of 45