Am123 - Check Coolant - Index MS24-6 Maintenance Instruction

Table of Contents

Advertisement

AM123
- Check coolant
Orientation
Requirement
32
For add-on equipment that cannot be cooled conventionally with cooling lubricants
or hydraulic fluid due to high temperature development, separate cooling is provided
in an independent cooling circuit. The coolant used here must be checked
continuously for its condition like other coolants.
Cooling diagram MS24-6/ MS32-6.3
1
"Cold" circuit
2
"Warm" circuit
3
Control cabinet cooling
4
Heat exchanger machine
5
Cooling water distribution unit
6
Heat exchanger cooling lubricant
The system comprises a cooling circuit on the machine side and either
1. a water recooler located next to the machine or
2. an external cooling circuit provided by the machine operator/owner.
Due to different requirements and/or specifications of the respective
manufacturers, be sure to review the respective manufacturer's
documentation!
For all work in connection with operating materials, the information in
the data sheets of the operating fluid manufacturers and the
information in the documents Notes on Operating Materials and
Transport, Installation, Commissioning must be observed.
When using a water recooler, be sure to follow the manufacturer's
instructions.