Technical Data - ESAB Warrior 400i CC/CV Instruction Manual

Hide thumbs Also See for Warrior 400i CC/CV:
Table of Contents

Advertisement

3 TECHNICAL DATA

3
TECHNICAL DATA
Mains voltage
Mains supply S
scmin
Mains supply Z
max
Primary current I
max
MIG/MAG
TIG
MMA
Idle power
Setting range
MIG/MAG
TIG
MMA
Permissible load at MIG/MAG
60 % duty cycle
100% duty cycle
Permissible load at TIG
60 % duty cycle
100% duty cycle
Permissible load at MMA
60 % duty cycle
100% duty cycle
Power factor at maximum current 0.91
Efficiency at maximum current
Electrode types
Open-circuit voltage
VRD deactivated
VRD activated
Apparent power at maximum
current
Active power at maximum
current
Operating temperature
Transportation temperature
Constant sound pressure when
idling
Dimensions l × w × h
0463 362 201
Warrior 400i CC/CV
380-415 V ±10%,
3~ 50/60 Hz
6.4 MVA
0.025 Ω
28 A
23 A
28 A
22.9 W
16 A/15 V - 400 A/34 V
5 A/10 V - 400 A/26 V
16 A/20 V - 400 A/36 V
400 A/34 V
300 A/29 V
400 A/26 V
300 A/22 V
400 A/36 V
300 A/32 V
90 %
Basic
Rutile
Cellulosic
56 V DC peak
28 V DC peak
18.0 kVA
16.4 kW
-10 to +40°C
-20 to +55°C
<70 db (A)
712 × 325 × 470 mm
- 9 -
Warrior 500i CC/CV
380-415 V ±10%,
3~ 50/60 Hz
7.2 MVA
0.022 Ω
37 A
30 A
38 A
21.3 W
16 A/15 V - 500 A/39 V
5 A/10 V - 500 A/30 V
16 A/20 V - 500 A/40 V
500 A/39 V
400 A/34 V
500 A/30 V
400 A/26 V
500 A/40 V
400 A/36 V
0.91
90 %
Basic
Rutile
Cellulosic
56 V DC peak
28 V DC peak
24.6 kVA
22.5 kW
-10 to +40°C
-20 to +55°C
<70 db (A)
712 × 325 × 470 mm
© ESAB AB 2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Warrior 500i cc/cv

Table of Contents