Booting The System; Autobooting The System; Sample Error Summary - DEC VAX 4000 300 Manual

Table of Contents

Advertisement

Figure 2–2: Sample Error Summary
KA670-A
Vn.n
VMB n.n
Performing normal system tests.
66..65..64..63..62..61..60..59..58..57..56..55..54..53..52..51..
50..49..48..47..46..45..44..43..42..41..40..39..38..37..36..35..
34..33..32..31..30..29..28..27..26..25..24..23..22..21..20..19..
18..17..16..15..14..13..12..11..10..09..08..07..
?5F 2 15 FF 0000 0000 02
P1=00000000
P2=00000002
P6=00000000
P7=00000000
r0=00000054
r1=20084019
r5=00000044
r6=000048DC
06..05..04..03..
Normal operation not possible.
>>>
If possible, print out the error summary and give it to your Digital service
representative.

2.4 Booting the System

VAX 4000 systems boot in one of two ways. You can configure the system
to autoboot on power-up or you can manually boot the system from console
mode. The Break Enable/Disable switch setting determines how the system
boots.

2.4.1 Autobooting the System

When the Break Enable/Disable switch is set to disable (the normal
operating setting), the system runs self-tests and, on completion, attempts
to load system software. Additionally, if the Break Enable/Disable switch
is set to enable, and the halt action
defined using the SET HALT command, the system will automatically
attempt to load system software.
Depending on whether or not a boot device has been selected, the system
loads system software or prompts you to select a boot device.
Loading System Software (With Boot Device Selected)
When a boot device has been selected, the system identifies the boot device
and the number ''2'' displays on the screen. As the system begins booting,
the countdown continues from 1 to 0.
2–6 VAX 4000 Model 300 Operation
; SUBTEST_5F_15, DE_SGEC.LIS
P3=5839FF00
P4=00000000
P8=00000000
P9=0000080A P10=00000003
r2=00008206
r3=00000000
r7=20008000
r8=00008000 EPC=FFFF90D6
or
REBOOT
RESTART_REBOOT
P5=00000000
r4=00004210
has been