return it to the out position. When the Halt button is returned to the out
position, the console mode prompt >>> is displayed on the console terminal
screen. Now you can enter console commands. If you inadvertently press
the Halt button, type ''c
'' to continue. Chapter 2 describes halting the
Return
system in more detail.
CAUTION: Pressing the Halt button halts the system regardless of the
setting of the Break Enable/Disable switch on the console module.
Below the Halt button is the Restart button. The Restart button has a
green indicator. When you press the Restart button, the system returns to
a power-up condition and self-tests are run. If you have specified a device
as the boot device and if the Break/Enable Disable switch is set to disable,
the system will reboot system software. Further instructions on restarting
your system are in Chapter 2.
NOTE: The Halt and Restart buttons can be disabled to prevent accidental
activation. Contact your Digital service representative if you want to disable
the controls on the SCP.
System Overview
1–9