Example B–5 shows the steps for examining and changing the allocation
class for a specified device. In the example, the allocation class is changed
from an allocation class of 0 to an allocation class of 2.
Example B–5: Setting Allocation Class for a Specified Device
PARAMS>SHOW ALLCLASS
Parameter
Current
--------- ----------------
ALLCLASS
PARAMS>SET ALLCLASS 2
PARAMS>SHOW ALLCLASS
Parameter
Current
--------- ----------------
ALLCLASS
B.3.3 Setting Unit Number
After entering the DUP driver utility for a specified device, you can examine
and set the unit number for the device as follows:
1. At the
prompt, enter
PARAMS>
of the ISE to which you are currently connected.
2. Enter
SET UNITNUM 10
3. Enter
SET FORCEUNI 0
supplied by the bus node ID plug.
4. Enter
SHOW UNITNUM
5. Enter
SHOW FORCEUNI
parameter is 0.
Example B–6 shows the steps for changing the unit number of a
specified device from unit number 0 to unit number 10.
6. Label the device with its unit number, using the unit number labels
shipped with your system. Figure B–3 shows where to affix a unit
number label on the device front panel.
B–10 VAX 4000 Model 300 Operation
Default
----------------
0
Default
----------------
2
SHOW UNITNUM
(or enter the unit number you desire).
to override the default unit number value
to verify the new unit number.
to verify that the current value for the
Type
Radix
--------
-----
0
Byte
Dec
Type
Radix
--------
-----
0
Byte
Dec
to check the unit number
FORCEUNI
B
B