Electrical Installation - FLOWTECH Flowpress Mini Single Operation And Maintenance Manual

Digital pressurisation unit
Table of Contents

Advertisement

5 ELECTRICAL INSTALLATION / EARTHING
5.11 Regulations: The electrical installation must be carried out in accordance with the
bolt
current national electrical regulations and installed by a qualified person.
5.12 Safety: In the interests of electrical safety a 30 mA residual current device (R.C.D.
not supplied) should be installed in the supply circuit.
This may be part of a consumer unit or a separate unit.
5.13 Before starting work on the electrical supply ensure power supply is isolated.
5.14 DO NOT allow the supply cord to contact hot surfaces, including the motor shell,
pump body or pipework. The cord should be safely routed and secured by cable clips.
5.15 Adjacent pipes: Adjacent suction and delivery pipes should be fitted with
earthing clamps in accordance with current regulations (Fig. 12).
5.16 Earthing: This appliance must be earthed via the supply cord.
5.17 Pipework: Copper or metallic pipework must have supplementary earth bonding where the
continuity has been broken by flexible hoses or plastic components.
5.18 Additional earthing: Certain installations may require additional earthing arrangements such as
equipotential bonding. Reference should be made to the relevant regulations concerning this subject
to ensure compliance.
5.19 Connections: The Flowpress Mini must be connected to a dedicated fused spur via a lockable
isolator to avoid authorized disconnection.
5.20 The electrical connection must be made adjacent to (not behind) the Flowpress Mini to allow
disconnection of the electrical supply should the pump module need to be removed for service or
maintenance.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Flowpress Mini Single and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Flowpress mini twin

Table of Contents