2.19 Static outlet pressure: The static outlet head must be 3 metres below pump
maximum cold fill pressure (vertically above the appliance).
2.20 Noise: A flexible hose is supplied as standard which will minimise the transmission of noise and
vibration from the Flowpress Mini pump to the pipework connected to the appliance outlet. However,
care must be taken when mounting the Flowpress Mini that any noise is not amplified through loose
panels or pipework.
2.21 Flexible hose: Only use the hose supplied with the Flowpress Mini.
2.22 Isolating valves: Separate system isolating valves (non-restrictive) must be fitted to allow easy
service of the Flowpress Mini. Isolating valves must be mounted where specified to allow the system
isolation and removal of the Flowpress Mini if needed. See Section 4.14 for installation details.