Parallel Operation - Champion Global Power Equipment 93001i-EU Operator's Manual

3000w portable inverter generator
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
93001i-EU - 3000W PORTAbLE INvERTER GENERATOR
Never exceed the specified capacity when adding loads to the
generator.
Eco (Economy) Mode
The Eco Mode button can be activated to turn on economy control
in order to minimize fuel consumption and noise while operating
the unit during times of reduced electrical output. Eco Mode
allows the engine speed to idle during periods of non-use.
The engine speed returns to normal when an electrical load is
connected. When the economy switch is off, the engine runs at
normal speed continuously.
For periods of high electrical load or momentary fluctuations,
the Eco Mode should be off.
12v DC Regulated Automotive Style Outlet
The 12V DC outlet(s) can be used with supplied accessories and
other commercially available 12V DC automotive style plugs.
Confirm the input voltage range of your item is at least 12-24V DC.
When charging a device, do not place near or on the exhaust
side of the generator. Extreme heat caused by exhaust
can damage the device and cause a potential fire hazard.
Prolonged exposure to engine exhaust can cause serious injury
or death.
Battery Charging
1. Before connecting the battery charging cable to a battery
that is installed in a vehicle, disconnect the vehicle battery
ground cable from the negative (–) battery terminal.
2. Plug the battery charging cable into the 12V DC receptacle of
the generator.
3. Connect the red (+) battery charger lead to the red (+) battery
terminal.
NOTICE
CAUTION
WARNING
4. Connect the black (–) battery charger lead to the black (–)
battery terminal.
5. Start the generator.
Important: The 12V DC outlet is ONLY to be used with supplied
accessories and other commercially available 12V DC automotive
style plugs. Be sure all electric devices including the lines and
plug connections are in good condition before connection to the
generator.
Do Not use both 230v AC and 12v DC at the same time
otherwise you could damage the generator or equipment
resulting in voiding your warranty.
Do not start the vehicle while the battery charging cable is
connected and the generator is running. It will not give the
battery a boost of power. The vehicle or the generator may
be damaged. Charge only vented wet lead acid batteries.
Other types of batteries may burst, causing personal injury or
damage.
Be sure all electric devices including the lines and plug
connections are in good condition before connection to the
generator.

Parallel Operation

The Champion model 93001i-EU is parallel ready and can be
operated in parallel with another Champion unit to increase the
total available electrical power. A Champion parallel kit (optional
equipment) is required for parallel operation. Model 500740-WL-
EU is the recommended model for this unit. For a list of compatible
models or to order a parallel kit, please call customer service at
+44(0)-1942-715-407 or visit www.championpowerequipment.
co.uk
Detailed instructions for parallel kit installation and operation of
the connected generators are provided in the parallel kit operator's
manual.
Stopping the Engine
1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Turn the EZ Start dial counter clockwise to the STOP position.
20
OPERATION
CAUTION
WARNING
NOTICE