when the average value changes.
· Press and hold the MAX/MIN/AVG-button [12]
to end MAX/MIN/AVG and return to normal
operations.
NOTE
MAX/MIN does not work on Frequency, Duty
Cycle, Capacitance or Temperature.
BACKLIGHT/HOLD-BUTTON
To freeze the reading on the LCD display, press
the HOLD-button [10]. The "HOLD" indicator [V]
will be displayed while the reading is being held.
Press the HOLD-button [10] again to exit HOLD
and return to normal operation.
· To turn the backlight in the display on, press
and hold the HOLD button until the backlight
turns on. To turn the backlight off, press and
hold the HOLD buttton until the backlight turns
off.
AUTO BACKLIGHT
6
When the meter is in the darkness, the backlight
can be automatically opened, not controlled by
the button.
FLASHLIGHT/PEAK-BUTTON
Press the PEAK-button [11] to turn the flashlight
on or off. The PEAK function is accessible when
measuring AC voltage or Current. It captures and
displays the highest positive peak and the high-
est negative peak of the AC waveform.
· Press and hold the PEAK-button [11] untill "Peak
MAX" [X] appears on the display. The meter
will display the highest reading and will update
the reading when a higher positive peak occurs.
· To view highest negative peak, press and hold
the PEAK-button [11] until "Peak MIN" [X]
apears on the display. The meter will display
and hold the largest negative reading. The
meter will update the reading when a larger
negative peak occurs.
· Press the PEAK-button [11] for approximately
one second to switch between Peak MAX and
Peak MIN readings.