Continuity Test - Futech MULTIPOWER 4.6 User Manual

Hide thumbs Also See for MULTIPOWER 4.6:
Table of Contents

Advertisement

· Set the rotary function switch [05] to the Ω/
position.
· Press the MODE-button [04] until the "Ω" sym-
bol [J] appears on the display.
· Insert the black test lead into the COM input
jack [08] and the red test lead into the Ω input
jack [09].
· Touch the test lead probes to the component
under test. If the component is installed in a
circuit, it is best to disconnect one side before
testing to eliminatie interferences with other
devices.
· Read the resistance on the display.

CONTINUITY TEST

NOTE
Never test continuity on a live circuit.
· Set the rotary function switch [05] to the Ω/
position.
· Press the MODE-button [04 ]until the " " symbol
[M] appears on the display.
· Insert the black test lead into the COM input
jack [08] and the red test lead into the Ω input
jack [09].
· Touch the test lead probes to the component
under test
· A beeper will sound if the resistance is approxi-
mately 50Ω or less and the resistance value will
be shown on the display.
+
11