Full Rated Output Not Reached; Max Pv Output Power Relates To Battery Voltage - Victron energy SmartSolar MPPT 150/45 Manual

Mppt solar charger
Hide thumbs Also See for SmartSolar MPPT 150/45:
Table of Contents

Advertisement

MPPT solar charger manual
VictronConnect history Pmax

9.5.3. Full rated output not reached

There are a few reasons why the solar charger is not reaching its full rated output.
Some of these reasons have already been explained in the the chapter: "The batteries take too long to charge, are undercharged
or charge current less than expected". Some additional reasons are explained in this paragraph.
PV array too small
If the PV array power rating is less than the solar charger nominal power rating, the solar charger cannot output more power than
the connected solar array can provide.
Temperature above 40°C
When the solar charger heats up, eventually the output current will derate. When the current is reduced naturally the output power
will reduce as well.
The controller is operational up to 60°C, with a full rated output up to 40°C.
In case the solar charger heats up quicker than expected, pay attention to the way it has been mounted. Mount it in such a way
that the generated heat can dissipate.
Ideally mount the solar charger on a vertical surface with the terminals facing downwards.
If the solar charger is located in a closed enclosure, such as a cabinet, make sure that cold air can enter and hot air can leave the
enclosure. Mount vents in the enclosure.
For very hot environments consider mechanical air extraction or provide air conditioning.

9.5.4. Max PV output power relates to battery voltage

The output current of the solar charger is current limited to its rated current. This means that the output power will vary, depending
on the voltage of the battery.
For example:
A 75/15 solar charger has an output current rating of 15A. This is the current that is going into the battery. This means that if the
solar charger is connected to a 12V battery you will get less power into your battery than with a 24V battery.
• For a 12V battery this is 15A x 12V = 180W.
• For a 24V battery this is 15A x 24V = 360W.
So, although a 360 W panel is connected to the solar charger, it will not be able to output the same power into a 12V battery than
it will when connected to a 24V battery.
Page 51
Troubleshooting and Support

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartsolar mppt 150/35Scc115045212

Table of Contents