Batteries Are Not Charged; Reverse Battery Polarity - Victron energy SmartSolar MPPT 150/45 Manual

Mppt solar charger
Hide thumbs Also See for SmartSolar MPPT 150/45:
Table of Contents

Advertisement

Battery voltage
Operational state
Correct voltage
Not powered
Powered, but not
Correct Voltage
charging

9.2. Batteries are not charged

This chapter lists all possible reasons why the solar charger does not charge the batteries, and the steps you can take to remedy
the situation.
There are a number of reasons why the solar charger might not charge the batteries.
For example:
• Issues with the battery, PV panels or system wiring.
• Incorrect settings.
• The solar charger is externally controlled.
• Natural battery behaviour.
In some of these cases the VictronConnect app will show, at the bottom of the status screen, a clickable link with the text "why is
the charger off". If the link is clicked, an explanation will appear as to why the charger is off.

9.2.1. Reverse battery polarity

Reverse polarity is when the positive and the negative battery cable have been accidentally swapped. The battery negative has
been connected to the positive solar charger terminal and the battery positive has been connected to the negative solar charger
terminal.
Page 41
MPPT solar charger manual
Action to take
There might be a fault with the controller.
Contact your Victron dealer or distributor.
Connect PV supply and check if battery charging starts. If charging does
not start, see chapter: " Batteries are not charged".
VictronConnect – link to "why is the charger off"
Examples of correct and incorrect (reverse) battery polarity
Troubleshooting and Support

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartsolar mppt 150/35Scc115045212

Table of Contents