To initiate the spark,
temporarily refit the control
knob to the spindle. Depress
the knob and while keeping it
depressed, turn to the 1/IGN
position. A spark should track
from the electrode pin to the
thermocouple tip. If there is
no spark or incorrect tracking,
check the spark gap between
the electrode wire and
thermocouple tip. See figure
5.
If the spark gap is correct,
check the ignition wiring.
5.3.9. If the fire is fitted to a
recessed fireplace, an
extension flue spigot up to a
maximum total length of
125mm may be used. The extension
must be a tight fit over the flue
spigot and be secured by two self
tapping screws. Note the minimum
clearance required as shown in
figure 2.

5.4 Fit The Closure Plate

See figure 6.
The closure plate has an opening
at the bottom for a central gas
feed pipe. The gap between the
pipe and this opening should be
sealed with tape after connection.
If a central feed pipe is not
required the opening should be
completely sealed with tape.
5.4.1 Hearth mounting
See figure 7.
The closure plate must be fitted and
sealed to the hearth and fireplace
opening using a suitable heat