open (unrestricted) position and in most cases no adjustment should be necessary. It can
be reset to a fully restricted position if the flue draught is excessive. The restrictor
must remain in its fully open position if the flue has an equivalent height of 4m or
less (as calculated in accordance with BS5440: Part 1 Appendix A) or where a pre-
cast flue is used.
To close the restrictor:
1. Loosen the screw situated behind the cut-out in the black upper heat shield. Do not
fully remove the screw.
2. Push the restrictor firmly down as far as it will go. The top of the slot in the restrictor
bracket should touch the screw.
3. Fully tighten the screw.
There may be certain exceptional circumstances where closing the restrictor causes the
fire to fail the spillage test (See section 9). In such cases the restrictor will have to be
reopened.
7 CONTROL & PRESSURE CHECKS

7.1 Check Control Settings

7.1.1 If closed
open the isolating valve at the inlet elbow.
,
7.1.2 To check the control positions temporarily place the outer case loosely over the
engine. Fit the control knob over the gas tap spindle.
7.1.3 Depress the control knob and turn anticlockwise partially towards the 1/IGN
position until some resistance is felt. Keep depressed at this position for a few seconds
to purge air from the system then, while keeping it depressed, turn fully to the 1/IGN
position. A spark should be generated at the pilot while turning. The spark should ignite
the pilot. If it does not, keeping the knob depressed, continue to turn the knob
anticlockwise. A second spark should be generated at the pilot while turning. This
spark should ignite the pilot
7.1.4 When pilot ignition has been achieved, keep the control knob depressed for
approximately ten seconds to allow the thermocouple probe to warm up and then release
it. If the pilot does not remain alight, ensure that the air has been purged, that the pilot
orifice is clear and that the thermocouple connections are sound. Replace the pilot unit
if necessary (see servicing section of this manual).