Valor Ultimate Installer's Manual page 10

Inset live fuel effect gas fire
Table of Contents

Advertisement

INSTALLER GUIDE
3.11 The minimum height from the top surface of the hearth to the underside of any
shelf made from wood or other combustible materials is detailed below.
• For a shelf up to 150mm deep: Minimum height = 750mm.
• For a shelf deeper than 150mm: 150mm + 12.5mm for every 25mm depth over
150mm. (See Graph 1)
Graph 1. Combustible shelf clearances
3.12 Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected by
heat. They may scorch or become discoloured when close to a heating appliance. Please
bear this in mind when installing.
3.13 The appliance must not be installed in any room, which contains a bath, or shower
or where steam is regularly present.
3.14 An extractor fan may only be used in the same room as this appliance, or in any
area from which ventilation for the appliance is taken, if it does not affect the safe
performance of the appliance. Note the spillage test requirements detailed further on in
this manual. If the fan is likely to affect the appliance, the appliance must not be
installed unless the fan is permanently disconnected.
3.15 Normal adventitious ventilation is usually sufficient to satisfy the ventilation
requirements of this appliance. In GB reference should be made to BS 5871 Part 2 and
in IE reference should be made to the current edition of IS 813 "Domestic gas
Page 10