The RUGGEDCOM RSG908C has passed the following Electromagnetic Compatibility (EMC) and environmental
tests.
EMC Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-9
IEC 61000-4-11
IEC 61000-4-16
IEC 61000-4-17
IEC 61000-4-18
36
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced (Conducted) RFI
Magnetic Field
Pulse Magnetic Field
Voltage Dips and Interrupts
Mains Frequency Voltage
Ripple on DC Power Supply
Damped Oscillatory Wave
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
± 4 kV @ 2.5 kHz, 5 kHz
DC Power Ports
± 4 kV @ 2.5 kHz, 5 kHz
AC Power Ports
± 4 kV @ 2.5 kHz, 5 kHz
Earth
± 4 kV @ 2.5 kHz, 5 kHz
Ground Ports
Signal Ports
± 4 kV Line-to-Ground
DC Power Ports
± 2 kV Line-to-Ground
AC Power Ports
± 4 kV Line-to-Ground
Signal Ports
DC Power Ports
AC Power Ports
Earth
Ground Ports
Enclosure Ports
100 A/m Continuous
Enclosure Ports
AC Power Ports
100% for 250 Cycles
Signal Ports
DC Power Ports
DC Power Ports
Slow Damped
Test Levels
± 8 kV
± 15 kV
20 V/m
± 2 kV Line-to-Line
± 1 kV Line-to-Line
± 2 kV Line-to-Line
10 V
10 V
10 V
10 V
1000 A/m for 1 s
300 A/m
30% for 0.5 Cycles
60% for 5 Cycles
30 V Continuous
300 V for 1 s
30 V Continuous
300 V for 1 s
15%
2.5 kV Common
EMC and Environmental Type Tests
RUGGEDCOM RSG908C
Installation Guide
Severity Levels
4
4
4
4
4
4
4
3
4
3
3
3
3
4
4
4
4
3