NOTICE
CAUTION/DOUBLE POLE
The fuses FUSE1 and FUSE2 are in the fuse holder (position
F6.3AH / 250 VAC.
NOTICE
Overvoltage protection for the power supply cables
If there is any possible overload of the power supply cables, suitable overvoltage protection
is necessary. Refer to the values on the type plate.
NOTICE
Reliable grounding
Reliable grounding of the devices mounted in the rack must be guaranteed. This applies, in
particular, to power supply cables that are not connected directly to the power supply
circuit. With the PS598-1 power supply unit, the IEC power connector (IEC 60320-1)
provides the connection to protective earth.
Pin assignment of the X2 socket on the front
Figure 6-5
Contact
L
M
M
L
SCALANCE XR-500
Operating Instructions, 09/2018, A5E03275845-12
Position of the socket X2 on the PS598-1 power supply unit
6.3 100 to 240 VAC power supply
). The fuses are of the type
Assignment
+24 VDC
Ground
Ground
+24 VDC
Connecting
67