Serial Interface - Siemens SCALANCE XM-400 Operating Instructions Manual

Simatic net industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

4.5

Serial interface

Information on the serial interface
● Via the serial interface on the device (RJ-11 jack), you can access the CLI of the device
● Access to the device is also possible independent of the Ethernet ports.
● To connect the serial interface to the PC, you require a cable with an RJ-11 plug and 9-
Position and assignment
Figure 4-3
Assignment of the terminal block
The supplied connecting cable has the following assignment:
Contact
1
2
3
4
5
6
7
8
9
SCALANCE XM-400
Operating Instructions, 05/2014, C79000-G8976-C306-03
directly via an RS-232 (115200 8N1) connection without assigning an IP address.
pin D-sub female connector. The connecting cable for the serial interface ships with the
device and can also be ordered as a spare part.
Position and pin assignment of the serial interface (RJ-11 jack) on the SCALANCE XM-
400 and the pin assignment of the D-sub female connector.
Pin assignment of the RJ-11 plug
-
-
TD (Transmit Data)
SG (Signal Ground)
RD (Receive Data)
-
4.5 Serial interface
Pin assignment of the D-sub female
connector
-
TD (Transmit Data)
RD (Receive Data)
-
SG (Signal Ground)
-
-
-
-
Connecting up