Removal And Insertion Of The C-Plug/Key-Plug - Siemens SIMATIC NET SCALANCE XR-500 Operating Instructions Manual

Table of Contents

Advertisement

Description of the device
4.4 C-PLUG / KEY-PLUG
4.4.2

Removal and insertion of the C-PLUG/KEY-PLUG

NOTICE
Do not remove or insert a C-PLUG/KEY-PLUG during operation
A C-PLUG/KEY-PLUG may only be removed or inserted when the device is turned off.
Position of the C-PLUG/KEY-PLUG with rack devices
Removing a C-PLUG/KEY-PLUG
Inserting a C-PLUG/KEY-PLUG
36
On a SCALANCE XR524-8C and SCALANCE XR526-8C,
the slot is below a cover on the left-hand side of the hous-
ing.
On a SCALANCE XR528-6M and SCALANCE XR552-12M,
the slot is below a cover on the right-hand side of the hous-
ing.
After undoing the screw (screw head Torx T10), you can
remove the cover plate and the slot is accessible.
1. Turn off the power to the device.
2. Remove the cover.
3. Insert a screwdriver between the front edge of the C-
PLUG/KEY-PLUG (position A) and the slot and release
the C-PLUG/KEY-PLUG.
4. Remove the C-PLUG/KEY-PLUG and screw the cover
plate firmly in place again.
1. Turn off the power to the device.
2. Remove the cover.
3. The housing of the C-PLUG/KEY-PLUG has a protrud-
ing ridge on the long side (position B). The slot has a
groove at this position. Insert the C-PLUG/KEY-PLUG
into the slot correctly aligned.
4. Secure the cover plate again with the screws.