Programming
5.3 Control Terminal Programming
Examples
Control terminals can be programmed.
•
Each terminal has specified functions it is capable
of performing
•
Parameters associated with the terminal enable
the function
•
For proper frequency converter functioning, the
control terminals must be
5
5
See Table 5.1 for control terminal parameter number and
default setting. (Default setting can change based on the
selection in 0-03 Regional Settings).
The following example shows accessing Terminal 18 to see
the default setting.
1.
Press [Main Menu] twice, scroll to parameter
group 5-** Digital In/Out Parameter Data Set and
press [OK].
Illustration 5.11
2.
Scroll to parameter group 5-1* Digital Inputs and
press [OK].
Illustration 5.12
3.
Scroll to 5-10 Terminal 18 Digital Input. Press [OK]
to access function choices. The default setting
Start is shown.
42
®
VLT
Operating Instructions
wired properly
programmed for the intended function
receiving a signal
14.6%
0.00A
Main Menu
2-** Brakes
3-** Reference / Ramps
4-** Limits / Warnings
5-** Digital In/Out
14.7%
0.00A
Digital In/Out
5-0* Digital I/O mode
5-1* Digital Inputs
5-4* Relays
5-5* Pulse Input
MG34U202 - VLT
Automation Drive D-Frame
Illustration 5.13
5.4 International/North American Default
Parameter Settings
Setting 0-03 Regional Settings [0] International or [1] North
America changes the default settings for some parameters.
Table 5.1 lists those parameters that are affected.
Parameter
0-03 Regional
Settings
0-71 Date Format
0-72 Time Format
1-20 Motor Power
[kW]
1(1)
1-21 Motor Power
[HP]
1-22 Motor Voltage 230 V/400 V/575 V
1-23 Motor
Frequency
3-03 Maximum
Reference
3-04 Reference
Function
4-13 Motor Speed
High Limit [RPM]
See Note 3
4-14 Motor Speed
High Limit [Hz]
1(1)
See Note 4
5-**
4-19 Max Output
Frequency
4-53 Warning Speed
High
5-12 Terminal 27
Digital Input
5-40 Function Relay Alarm
6-15 Terminal 53
High Ref./Feedb.
Value
6-50 Terminal 42
Output
14-20 Reset Mode
®
is a registered Danfoss trademark
14.7%
0.00A
Digital Inputs
5-10 Terminal 18 Digital
Input
[8]] Start
International
North American
default parameter
default parameter
value
value
International
North America
DD-MM-YYYY
MM/DD/YYYY
24 h
12 h
See Note 1
See Note 1
See Note 2
See Note 2
208 V/460 V/575 V
50 Hz
60 Hz
50 Hz
60 Hz
Sum
External/Preset
1500 RPM
1800 RPM
50 Hz
60 Hz
100 Hz
120 Hz
1500 RPM
1800 RPM
Coast inverse
External interlock
No alarm
50
60
Speed 0-HighLim
Speed 4-20 mA
Manual reset
Infinite auto reset
1(1)
5-1*