Wiring & Power Connections; Table 6. Exhaust Connection Requirements - Despatch LCC Series Owner's Manual

Stackable oven
Hide thumbs Also See for LCC Series:
Table of Contents

Advertisement

LCC_LCD1-16/51 Oven Owner's Manual
Warning!
Do not be careless about restrictions in and around the fresh air
and exhaust openings and stacks.
If more than two elbows are used in the stack, overall airflow will
Notice
be reduced. If airflow is reduced, the amount of solvent that can
be safely used with the equipment must also be reduced.
Make sure exhaust piping materials can withstand maximum
exhaust temperatures (Table 6).
Connection
Exhaust Size
Exhaust Flow
Temperature:
LCC Series -
Temperature:
LCD Series -
5.2.4. Wiring & Power Connections
See electrical schematics for line connections.
Danger!
Contact with energized electrical sources may result in serious
injury or death. All wiring to be completed by properly trained
and licensed personnel.
©2021 ITW EAE. All rights reserved. Despatch is a registered trademark in the U.S. and other
countries. No part of the contents of this manual may be reproduced, copied or transmitted in any form
or by any means without the written permission from ITW EAE - Despatch, unless for purchaser's
personal use.

Table 6. Exhaust Connection Requirements.

LCC/LCD1-16 Models
1.88" x 2.88" (48.0 mm x 73.4 mm)
35 CFM (991.5 lpm)
LCC/LCD1-51 Models
73 CFM (2067 lpm)
260°C(500°F)
350°C(662°F)
C244, 320207, REV B