Figure 11. Lcc/Lcd Oven Utility Connections - Despatch LCC Series Owner's Manual

Stackable oven
Hide thumbs Also See for LCC Series:
Table of Contents

Advertisement

LCC_LCD1-16/51 Oven Owner's Manual
Nitrogen inlet
Water outlet
5.2.2.1. Nitrogen with Water-Cooled Models
1. Connect nitrogen supply line to NITROGEN INLET on the rear right of the
oven (Figure 11).
Nitrogen pressure supplied should run at 70 psi (4.83 bar) but not
more than 80 psi (5.52 bar). Check for leaks.
2. Install water connection for cooling coils to WATER INLET (Figure 11).Verify
the valve on the flowmeter is turned OFF, that is, fully clockwise.
Water pressure supplied to the oven must not exceed 100 psi (6.89
bar). Despatch recommends installing a regulator to prevent
surging.
3. Check for leaks by slowly opening the valve on the flowmeter and allowing
any air to bleed out.
©2021 ITW EAE. All rights reserved. Despatch is a registered trademark in the U.S. and other
countries. No part of the contents of this manual may be reproduced, copied or transmitted in any form
or by any means without the written permission from ITW EAE - Despatch, unless for purchaser's
personal use.

Figure 11. LCC/LCD Oven Utility Connections.