Supply Of Combustion Air - ADURO H1 LUX User Manual

Hide thumbs Also See for H1 LUX:
Table of Contents

Advertisement

Available languages

Available languages

Please ensure that all local rules and regulations are complied with, including CE marking of the exhaust
connector. Additionally, distance requirements to flammable material for the exhaust connector must be
respected.
2.3 Connection to a brick chimney
If the stove is being connected to a brick chimney, the rear outlet should be used, or a curved flue pipe via
the top outlet. After measurement, a hole is made in the chimney in which the pipe sleeve is placed and
fireplace mortar is used to seal it in place. The stove is placed in position and the flue pipe is put in place. A
thin gasket is placed between the flue pipe and the pipe sleeve to seal the joints. The flue pipe should
protrude into the pipe sleeve, but must not block the opening in the chimney (see the illustration below).
X
The Aduro H1 & H3 LUX can be connected to a chimney to which other heat sources are connected.

2.4 Supply of combustion air

All wood burning stoves need constant supply of air to ensure a
clean and efficient combustion. This is often a problem in
modern energy-efficient houses that are very tight. Therefore,
the Aduro H1 & H3 LUX is equipped with external supply of
combustion air, where the air to the combustion is supplied from
the outside and directly into the wood burning stove. Air from
outside can be provided through a channel, which is connected
to the connecting pipe under the combustion chamber. The
amount of air needed for combustion is 25 m3/h.
The connecting pipe has an external diameter of 78 mm, to
which you need a pipe with a diameter of 80 mm. If the pipe
work is further than 1 m the pipe diameter must be increased to
100 mm and a correspondingly larger wall valve must be
chosen. In warm rooms the channel should be insulated with 30 mm mineral wool covered with a damp-proof
course (plastic). It is important that the lead-in between the pipe and the wall (or floor) is sealed with jointing
compound. You can eventually use the complete Aduro fresh air kit.
2.5 Aduro Hybrid App
It is possible to control Aduro H1 & H3 LUX in three ways:
1. Through the control panel on the stove.
2. Through the app Aduro Hybrid 1 and the Wi-Fi module "Aduro" in the near of the stove
54

Advertisement

Table of Contents
loading

This manual is also suitable for:

H3 luxEn13240En14785Ns3058

Table of Contents