If an appliance begins to operate abnormally, becomes
sluggish or stops suddenly, turn it off immediately. Then
disconnect the appliance from receptacles of the Parallel Kit 2,
and determine whether the problem is the appliance, or if the
rated load capacity of the generator has been exceeded.
The ECO Switch 3 must be in the same position on both
generators.
Make sure that the electrical appliance rated power does not
exceed the total rated power of two generators.
Most motorized appliances require more than their rated
wattage for startup. When an electric motor is started, the
OVERLOAD LED (red) 5 may come on. This is normal if the
OVERLOAD LED (red) 5 goes off after a few seconds.
If the generators are overloaded, or if there is a short circuit in
a connected appliance, the OVERLOAD LED (red) 5 will go on,
and the current to the connected appliances will shut off, and
the READY LED (green) 4 will go off. Stop the engines and
investigate the problem.

8.2 STOP AC PARALLEL

Once the generators are no longer needed they can be shut down:
(1). Disconnect or turn off all electrical loads from receptacles of the
Parallel Kit 2.
(2). Stop the engine one by one as follows:
Turn the Fuel Tap to the "OFF" position.
Turn the Engine Switch to "OFF" position.
(3). Allow the generator to cool before moving or storing.