Advertisement

EZV SERIES
USER GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Energizer EZV SERIES

  • Page 1 EZV SERIES USER GUIDE...
  • Page 2 The engine exhaust from this product contains chemicals known to cause cancer, birth defects or other reproductive harm. ©2015 Energizer Power Equipment. All Rights Reserved. Licensed by Energizer Corporation, United States of America. EZV_UG_EN_2015-06-22...
  • Page 3 Let's get started. You're excited to power up, so we'll keep this brief!
  • Page 4 THIS PRODUCT MEETS ALL CERTIFICATION REQUIREMENTS FROM:...
  • Page 5 WE'VE GOT YOU COVERED! Contact us by phone at 1-887-528-3772, email us at support@energizergenerators.com, or visit us online at www.energizergenerators.com. SAVE THESE INSTRUCTIONS - This user guide contains important instructions for your product, that should be followed during installation and mainteneance of the generator and batteries.
  • Page 6: Warranty Information

    Product registration is required for all product support and warranty coverage. Warranty support, operation assistance and product support is provided by Midland Power Inc., a licensed manufacturer of Energizer Generators. Please contact us directly for any warranty service questions. 1-877-528-3772 support@energizergenerators.com...
  • Page 7: Table Of Contents

    CONTENTS PAGE Safety First Safety while using your generator Understanding AC safety Safety while maintaining your generator Other safety tips Learn About Your Generator Identification of componants Making sure you have everything Setting Up Your Generator Checking the oil level Checking the air filter Using Your Generator Initial startup of your generator...
  • Page 8: Safety First

    Chapter 1 — Safety First Playing it safe when working with power equipment is always a good idea. Here are some important precautions to make sure you stay safe. 1.1 Safety while Operating Your Generator • Always perform an oil, fuel and air filter check before starting the engine. Properly clean and maintain the equipment.
  • Page 9: Understanding Ac Safety

    operation. • Do not operate the generator in rain or snow. Do not allow any moisture to come in contact with the generator. • • Do not touch the spark plug while the engine is operating or shortly after the engine has been shut down 1.2 Understanding AC Safety Before connecting the generator to an electrical device or power cord: Make sure that everything is in proper working order.
  • Page 10: Other Safety Tips

    Do not clean the filter element with flammable liquids like gasoline because • an explosion may occur. Turn off the engine before performing any maintenance. Otherwise it can • cause severe personal injury or death. Allow the generator set to cool down before performing any maintenance. •...
  • Page 11: Learn About Your Generator

    Chapter 2 — Learn About Your Generator This section will show you how to identify key parts of your generator. Going over the terminology below will make sure we're on the same page. 2.1 Identification of Components Choke Lever Fuel Cap Fuel Valve Control Panel Engine Access...
  • Page 12 Output Overload Low Oil Outlet Light Light Light On/Off Ignition Switch AC Dual Outlet DC Reset 20A Circuit Breaker DC Outlet EcoMode Ground Switch 120V 30A EcoMode Output Overload Low Oil Outlet Switch Light Light Light On/Off Ignition AC Dual Switch Outlet 20A Circuit...
  • Page 13: Making Sure You Have Everything

    Make Sure You Have Everything Part Name Quantity EZV series Generator User Guide DC Charging Cables 450mL 10W30 Oil with Funnel Tool Kit Make sure your generator set has everything in the table above.
  • Page 14: Setting Up Your Generator

    Chapter 3 — Setting Up your EZV series Generator Setup should be done every time you start up your generator, these quick checks will ensure you get the most out of your generator. Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area.
  • Page 15: Checking The Air Filter

    Gasoline substitutes are not recommended. They may be harmful to the fuel system components. Gasoline is highly flammable and explosive under certain conditions. Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow open flames or sparks in the area where the generator is being Maximum Oil Level refueled or where gasoline is stored.
  • Page 16 Chapter 4 — Using Your EZV series Generator DANGER - CARBON MONOXIDE Using a generator indoors WILL KILL YOU IN MINUTES. Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust you are breathing CO.
  • Page 17: Using Your Generator

    Initial Setup of Your Generator We know you're excited to get using your generator. Please be sure to follow the setup, operation, and shut off instructions below thoroughly to ensure the best lifespan for your generator. Steps 1-3 are for the EZV2800 only. If you have an EZV2200 start on Step 4. 1.
  • Page 18 5. Locate, unscrew, and remove the Oil Dipstick, exposing the internal engine compartment. Be sure not to allow any dust or debris near the engine during this time. 6. Pour in the full contents of the 450 mL oil bottle provided with your unit, or fill to the full mark located on the dipstick.
  • Page 19: Operating Your Generator

    Operating Your Generator Before using generator, a ground wire must be connected to the ground terminal. The Ground terminal is located on the Front Panel. Before using the ground terminal consult a qualified electrician. 1. Disconnect all devices from the generator. 2.
  • Page 20 (EZV2800 only, for EZV2200 proceed to step 5b) Turn Power switch to "Start" for 5 seconds to start engine. If the engine does not start, the battery may be dead, proceed to step 5b to start the engine. Running the engine charges the battery.
  • Page 21: Shutting Off Your Generator

    Shutting Off Your Generator 1. Disconnect all devices from the generator. 2. Turn EcoMode switch to "Off". Let generator run with EcoMode off for 2 minutes. 3. Turn Power switch to "Off". 4. Close the fuel valve by turning it to "Off". To stop the engine in an emergency, turn the engine switch “OFF”.
  • Page 22: Using Your Generator With Appliances

    See Section 4.5 before using the DC outlet. 3. You can now turn your devices on and use them. 4.5 Using an EZV series generator to Charge Automotive Batteries You can use 12V 8.3A DC output to charge automotive batteries. Be sure to monitor the battery charge time.
  • Page 23 1. Connect the positive (red) terminal of the battery to the red (positive) terminal, the 12V 8.3A DC Output Terminal on the front panel of your generator. 2. Connect the negative (black) terminal of the battery to the black (negative) terminal, the 12V 8.3A DC output terminal on the front panel of your generator.
  • Page 24: Maintaining Your Generator

    Chapter 5 — Maintaining Your EZV series Generator Proper maintenance ensures safe, economical and trouble-free operation. Improper maintenance may cause the generator to malfunction and can lead to serious injuries. Contact Energizer Power Customer Support if you have any maintenance questions. 5.1 Maintenance Schedule Every...
  • Page 25: Cleaning The Air Filter

    5.2 General Inspection Tips 1. Look for fuel leaks around the fuel tank, fuel hose, and fuel valve. Close the fuel valve and repair leaks immediately. 2. Look and listen for exhaust leaks while the engine is running. Have all the leaks repaired before continuing operation.
  • Page 26: Changing The Engine Oil

    5.4 - Changing the Engine Oil Used motor oil can cause skin irritations if left in long-term contact with skin. Wash hands thoroughly with soap and water after handling oil. Do not dispose of used oil in drains or soil. Local service shops provide environmentally-friendly disposal methods.
  • Page 27: Replacing And Cleaning The Spark Plug

    5.5 - Replacing and Cleaning the Spark Plug Do not rinse spark plug in water. Follow guidelines and be careful not to overtighten the spark plug. Tighten ½ turn when installing a new spark plug. Tighten ¼ turn when re-installing an old spark plug. 1.
  • Page 28: Handling And Storage

    5.6 - Handling and Storage Handling 1. Turn off the power switch and the fuel valve when transporting the generator set. 2. Do not touch engine until the engine has cooled down. 3. Keep the generator at a level position in order to prevent spillage. Storage Before storing the generator set for an extended period: 1.
  • Page 29: Troubleshooting

    6.0 Troubleshooting Common issues can be fixed by following the instructions in this guide. If the unit will not function after following these instructions, contact technical support before attempting to use or repair the product. PROBLEM SYMPTOMS CORRECTION Generator will Generator will 3.
  • Page 30 Generator does No indicator 1. Generator circuit breaker off or tripped not produce lights or display 2. Remove all loads, reset breaker, and check device power on front panel for defects. Do not exceed generator rating. Generator does Overload 1. Adjust choke lever according to instructions on not produce indicator light page 20...
  • Page 31 26. 6. Fouled spark plug, replace with equal or greater quality plug. Refer below for a complete list of spark plug compatibility codes. SPARK PLUG COMPATIBILITY BRAND EZV SERIES CR7HS DENSO U20FPR CHAMPION RZ10YC BOSCH...
  • Page 32: Specifications

    Chapter 7- Specifications EZV2200 EZV2800 Rated frequency (Hz) Rated AC Output Power (W) 2000 2600 Max AC Output Power (W) 2200 2800 1-Phase Rated AC Voltage (V) Power Factor Max DC Output Power (W) Rated DC Voltage (V) 3.80 HP, Single Cylinder, forced 5.3 HP, Single Cylinder, forced Type air cooling, 4-stroke, OHV...
  • Page 33: Wiring Diagram

    Chapter 8- Wiring Diagram...
  • Page 34: Learn About Your Warranty

    This limited warranty is valid for residential or recreational applications only and only when the generator receives all necessary preventative maintenance as described in the Energizer Generators User Guide. The repair or replacement of a generator will take place within a reason- able period of time during normal business hours.
  • Page 35 EXCLUSIONS NOT COVERED BY THIS LIMITED WARRANTY 1. Normal engine/alternator wear. 2. Damage caused by lack of maintenance as described in the Energizer User Guides, or negligence by using improper or impure motor oil, coolant, or fuel. 3. Damage caused by accidents, improper installation or storage.
  • Page 36 7. Items not supplied by Energizer, including, but not limited to, starting batteries, battery cables, external wiring, fuel lines, filters, etc; (refer to exclusions). 8. Repairs made during the warranty period, without first obtaining a case number from Energizer. Batteries supplied with any generator product should be considered a bonus item and not covered by warranty.
  • Page 37 EMISSION CONTROL SYSTEM WARRANTY Your new Midland Power Inc. engine complies with the U.S. EPA (Environmental Protection Agency) regulations, State of California emission regulations (models certified for sale in California only) and Canada EPA regulations. Midland Power Inc. provides the emission warranty coverage for engines in the United States and its territories.
  • Page 38 EMISSION CONTROL SYSTEM WARRANTY PARTS: Systems Covered in Parts Description Warranty Carburetor assembly (includes starting enrichment system), Fuel Metering Engine temperature sensor, Engine control module, Fuel regulator, Intake manifold Fuel Tank, Fuel Cap, Fuel Hoses, Vapor Hoses, Carbon Canister, Canister Mounting Brackets, Fuel Strainer, Fuel Evaporative cock, Fuel Pump, Fuel Hose Joint, Canister Purge Hose Joint...
  • Page 39 Warranty Registration Instructions: Ownership must be registered with Energizer Power Equipment in order to ensure continued warranty and service support. Please fill out the registration card below and mail it along with a copy of your receipt, and the original UPC barcode from your product packaging. The store, date of purchase and product purchase should be clearly visible on the receipt copy.
  • Page 41 Ownership and Warranty Transfer Instructions: Changes in ownership must be registered with Energizer Power Equipment in order to ensure continued warranty and service support. Warranty support cannot be provided without registration (from original date of purchase and after transfer of ownership) This transfer form must be completed on or before the date that ownership change takes effect.
  • Page 43 Enjoy! Be sure to check energizergenerators.com monthly for updates regarding your generator.

This manual is also suitable for:

Ezv2200Ezv2800

Table of Contents