"ON" position
Be sure any electric devices are turned off before plugging them in.
NOTE
The ECO Switch 1 must be turned to "OFF" position when
using electric devices that require a large starting current, such
as a heavy compressor or some high electrical loads.
Be sure all electric devices including the lines and plug
connections are in good condition before connection to the
generator.
Be sure the total load is within generator rated output.
Be sure the receptacle load current is within receptacle rated
current.
Be sure to ground (Earth) the generator when the electric
device is earthed.
If the generator is overloaded (in excess of rated power), or if
there is a short circuit in a connected appliance, the
OVERLOAD LED (red) 5 will go ON, and the current to the
connected appliance(s) will shut off, and the READY LED
(green) 4 will go OFF.
The Reset Button 3 can be used to recover output of the
generator under the condition of overload protection, and
unnecessary to restart engine overall. But at first check and
correct the problem, if there is a short circuit in a
"OFF" position
- 40 -
connected