electric shock. If it needs to be replaced with another cut-out, the latter must correspond
to the technical specifications of the generator. Due to important mechanical constraints,
it is necessary to use a flexible sheathed cable with a strong rubber protective layer
(conforming to IEC 245-4) or a similar cable. If using an electrical extension cable, the
total length of the extension must not exceed 60m when the section of the wire is
2
1.5mm
and must not exceed 100m when the section of the wire is 2.5mm
Additional requirements for low-power generating sets for use by laymen
Protect children by keeping them at a safe distance from the generating set.
Fuel is combustible and easily ignited. Do not refuel during operation. Do not
refuel while smoking or near naked flames. Do not spill fuel.
Some parts of the internal combustion engine are hot and may cause burns. Pay
attention to the warnings on the generating set.
Engine exhaust gases are toxic. Do not operate the generating set in
unventilated rooms. When installed in ventilated rooms, additional
requirements for fire and explosion protection shall be observed.
Before use, the generating set and its electrical equipment (including lines and
plug connections) should be checked to ensure that they are not defective.
Protection against electrical shock depends on circuit breakers specially
matched to the generating set. If the circuit breakers require replacement, they
should be replaced with a circuit breaker having identical ratings and
performances characteristics.