Table 128. Post Error Beep Codes; Table 129. Bmc Beep Codes - Intel SC5650HCBRP Product Specification

Hide thumbs Also See for SC5650HCBRP:
Table of Contents

Advertisement

Intel® Server System SC5650HCBRP TPS
POST Error Beep Codes
The following table lists the POST error beep codes. Prior to system video initialization, the
BIOS uses these beep codes to inform users of error conditions. The beep code is followed by a
user-visible code on the POST Progress LED's.
Beeps
Error Message
3
Memory error
The BMC may generate beep codes upon detection of failure conditions. Beep codes are
sounded each time the problem is discovered, such as on each power-up attempt but are not
sounded continuously. Each digit in the code is represented by a sequence of beeps whose
count is equal to the digit.
Code
1-5-2-1
CPU: Empty slot / Population error
1-5-4-2
Power fault: DC power unexpectedly lost (power good dropout).
1-5-4-4
Power control fault (power good assertion timeout).
Revision 1.2

Table 128. POST Error Beep Codes

POST Progress Code
Multiple
System halted because a fatal error related to the memory was
detected.

Table 129. BMC Beep Codes

Reason for Beep
Intel order number E81443-002
Appendix F: POST Error Messages and Handling
Description
Associated Sensors
CPU sockets are populated incorrectly – CPU1
must be populated before CPU2.
Power unit – power unit failure offset.
Power unit – soft power control failure offset.
209

Advertisement

Table of Contents
loading

Table of Contents