SECTION 7 − OPERATING AUXILIARY EQUIPMENT

7-1. Generator Power Receptacles

1
1
120 V 20 A AC Receptacle RC12
2
120 V 20 A AC GFCI Receptacle
GFCI1
3
240 V 20 A AC Receptacle RC11
RC12 and GFCI1 supply 60 Hz single-
phase power at weld/power speed.
Maximum output from each receptacle is
2.4 kVA/kW.
If a ground fault is detected, GFCI Reset
button pops out and receptacle does not
work. Check for faulty equipment plugged
in receptacle. Press button to reset GFCI
receptacle.
OM-247 432 Page 34
3
2
.
At least once a month, run engine at
weld/power speed and press test but-
ton to verify GFCI is working properly.
RC11 supplies 60 Hz single-phase power
at weld/power speed. Maximum output
from RC11 is 4 kVA/kW.
4
Supplementary Protector CB6
5
Supplementary Protector CB4
6
Supplementary Protector CB5
CB4 protects GFCI1 and CB6 protects
RC12 from overload. If a supplementary
protector opens, the receptacle does not
work. Press button to reset.
4
5
6
1
z
6 0 H
Supplementary protector CB5 protects re-
ceptacles and the generator winding from
overload. If CB5 opens, the receptacles do
not work. Place CB5 switch in On position
to reset circuit breaker.
.
If a supplementary protector continues
to open, contact Factory Authorized
Service Agent.
.
Generator power decreases as weld
output increases.
Combined output of all receptacles is limit-
ed to the 4 kVA/kw rating of the generator.
245 609