PRINTER ENGINE SERVICE MODE
SP1
Mode Number
1105*
04
Ends (By-pass)
05
Center (Reload)
06
Ends (Reload)
07
Roller Center (By-pass)
Thick Paper
08
Roller Ends (By-pass)
Thick Paper
09
Roller Center (Thick Paper)
10
Roller Ends (Thick Paper)
1106
Temperature Display
Sets the temperature display to show the fusing temperature (monitored by
thermistors) for the center or ends of the hot roller, or the temperature of the I/O
Board at power on.
01
Roller Center
02
Roller Ends
03
I/O Temp.
Function and [Setting]
[120°C ~ 220°C / 190° ° ° ° C / 1°C step]
Adjusts the temperature for re-heating the center
of the hot roller:
Reload Temp. = Fusing. Temp – SP Value
[0°C ~ 60°C / 30° ° ° ° C / 1°C step]
When the fusing temperature exceeds this
setting, the machine can operate.
Do not set a reload temperature (Spec. Temp –
SP Value) higher than the SP1105-02 setting.
Adjusts the temperature for re-heating the ends
of the hot roller:
Reload Temp. = Fusing. Temp – SP Value
[0°C ~ 60°C / 30° ° ° ° C / 1°C step]
When the fusing temperature exceeds this
setting, the machine can operate.
Do not set a reload temperature (Spec. Temp –
SP Value) higher than the SP1105-02 setting.
Adjusts the temperature of the center of the hot
roller for feeding thick paper with the by-pass
tray.
[120°C ~ 220°C / 200° ° ° ° C / 1°C step]
Adjusts the temperature of the ends of the hot
roller for feeding thick paper with the by-pass
tray.
[120°C ~ 220°C / 200° ° ° ° C / 1°C step]
Adjusts the temperature for re-heating the center
of the hot roller for feeding thick paper:
Reload Temp. = Fusing. Temp – SP Value
[0°C ~ 60° ° ° ° C / 5° ° ° ° C / 1°C step]
When the fusing temperature exceeds this
setting, the machine can operate.
Do not set a reload temperature (Spec. Temp –
SP Value) higher than the SP1105-02 setting.
Adjusts the temperature for re-heating the ends
of the hot roller for feeding thick paper:
Reload Temp. = Fusing. Temp – SP Value
[0°C ~ 60°C / 5° ° ° ° C / 1°C step]
When the fusing temperature exceeds this
setting, the machine can operate.
Do not set a reload temperature (Spec. Temp –
SP Value) higher than the SP1105-02 setting.
Monitors and displays temperature (°C) of the
hot roller center.
Monitors and displays temperature (°C) of the
hot roller ends.
Monitors and displays the temperature (°C) of
the I/O board at power on.
5-8