Ricoh A-P3 Service Manual page 122

Table of Contents

Advertisement

6 November, 2001
SC
Level
621
C
Communication timeout error
between BICU and finisher or
mailbox
A break (low) signal is received from
the finisher or the mailbox.
623
C
Communication timeout error
between BICU and paper tray unit
The BICU does not receive a
response after 3 attempts within 100
ms to send data to the paper tray
unit.
624
C
Communication break error between
BICU and paper tray unit
The BICU cannot communicate with
the paper tray unit because it has
received a break signal.
626
C
Communication timeout error
between BICU and LCT
The BICU does not receive a
response after 3 attempts within 100
ms to send data to the LCT.
627
C
Communication break error between
BICU and LCT
The BICU cannot communicate with
the LCT unit because it has received
a break signal.
640
D
BICU control data transfer sumcheck
error
A sampling of control data sent from
the BICU to the controller reveals a
sumcheck error. Only the logging
count is performed.
641
D
BICU control data transfer abnormal
Data send from BICU to controller
failed after 3 attempts.
690
A
GAVD block I
An error is detected in the GAVD
communication I
the GABIC2.
691
A
GAVD FCI block I
An error is detected in the FCI
communication I
the GABIC2.
Symptom
2
C bus error
2
C control register of
2
C bus error
2
C control register of
4-9
SERVICE CALL CONDITIONS
Possible Cause
• Serial line connecting BICU and
finisher unstable
• External noise
• Serial line connecting BICU and
paper tray unit unstable
• External noise
• BICU board and paper tray main
board connection defective or
loose
• Paper tray main board defective
• BICU board defective
• Serial line connecting BICU and
paper tray unit unstable
• External noise
• BICU board and LCT main board
connection defective or loose
• Optional paper feed unit interface
board defective
• BICU board defective
• Serial line connecting BICU and
LCT unit unstable
• External noise
• BICU board and LCT main board
connection defective or loose
• LCT interface board defective
• BICU board defective
• Serial line connecting BICU and
LCT unit unstable
• External noise
• BICU board and LCT main board
connection defective or loose
• LCT interface board defective
• BICU board defective
• Controller board defective
• External noise
• BICU board defective
• Controller board defective
• External noise
• BICU board defective
• I2C bus on BICU defective
• I2C bus on BICU defective

Advertisement

Table of Contents
loading

This manual is also suitable for:

G065

Table of Contents