6 November, 2001
MAILBOX INSTALLATION (G909)
[B]
[A]
[C]
[D]
[E]
G909I550.WMF
5. Attach the cushion [A] to the position [B].
6. Open the front cover [C] of the mailbox, and remove the screw [D] that secures
the locking lever [E]. Then pull the locking lever.
1-25