18
TZIDC-210, TZIDC-220 DIGITAL POSITIONER | OI/TZIDC-210/TZIDC-220-EN REV. G
... 2 Use in potentially explosive atmospheres
... TZIDC-210 – Ex relevant specification

EAC TR-CU-012 Ex d

Ex marking
Marking
1Ex d IIC T6...Т4 Gb Х
Certificate
EAC TR-CU-012
Type
TZIDC-210 Doc. 901132
Device class
II 2 G
Standards
EN 60079-0, EN 60079-1
Special conditions
Before final installation, the operator needs to decide on the
use of the device, either
A) as a device with 'Ex i' intrinsically safe type of protection
or
B) as a device with 'Ex d' type of protection
and permanently mark the selected type of use on the name
plate. Specific conditions of the surrounding environment,
such as chemical corrosion, must be taken into account when
affixing the permanent mark. Only the manufacturer must
change the selected type of use following a re-examination
Variants that, according to declarations, also meet the
requirements for the 'intrinsically safe' type of protection
may no longer be used as 'intrinsically safe' if they have been
previously used as a flameproof type of protection
Secure cable entries against twisting and loosening by using
a (medium-strength) securing adhesive.
In the case of high torsional forces, the bearing sleeves must
be replaced due to wear on the shaft for the position pickoff
(significant control deviation).
If the positioner is operated at an ambient temperature
above 60 °C (140 °F) or below −20 °C (−4 °F), make sure to
use cable entries and lines suited for an operating
temperature corresponding to the maximum ambient
temperature increased by 10 K or corresponding to the
minimum ambient temperature, respectively.
Screws that comply with the minimum requirements of the
A2-70, A2-80 or 10.12 quality grades must be used to close
the flameproof enclosure.

EAC TR-CU-012 Ex i

Ex marking
Marking
Certificate
Type
Standards
Temperature data
Device group II 2 G
Temperature class
Ambient temperature Ta
T4
−40 to 85 °C
T5
−40 to 50 °C
−40 to 40 °C *
T6
*
*
When using the plug−in module for 'Digital Feedback' in Temperature
Class T6, the maximum permissible ambient temperature range is
−40 to 35 °C (−40 to 95 °F).
Temperature characteristic curves
Intrinsically safe circuit according to ATEX, IECEx and EAC /
TR CU 012/2011
Device category 1: Use in Zone 0
Device category 2: Use in Zone 1
Device category 3: Use in Zone 2
Electric data for ia / ib / ic for groups IIB / IIC
With the intrinsically safe Ex i IIC type of ignition protection, only
for connection to a certified FISCO power supply unit or a
barrier, i.e., a power supply unit with maximum values according
to the following table:
Current circuit (terminal)
Electrical information (maximum values)
Signal circuit
U
i
(+11 / -12)
I
= 250 mA
i
P
i
1Ex ia IIC T6/Т4 Gb Х
1Ex ib IIC T6/Т4 Gb Х
2Ex ic IIC T6/Т4 Gc Х
EAC TR-CU-012
TZIDC-210
EN 60079-0, EN 60079-11
= 24 V
C
< 5 nF
i
L
< 10 μH
i
= 1.2 W
Characteristic curve =
linear