Coin Mechanism Errors - BRAVILOR BONAMAT Sego Technical Manual

Hide thumbs Also See for Sego:
Table of Contents

Advertisement

code
description
02002
fill up 3 times without
selection
02101
break temperature
sensor boiler
02102
short-circuit
temperature sensor
boiler
02201
no pulse detection
water selector sensor
02202
water selector in
wrong position
04301
rotation brewer does
not move
04401
water counter gives
no pulses
10001
general I/O error

3.2 Coin mechanism errors

code
description
07001
coin mechanism missing
07002
coin mechanism defective
07003
coin mechanism blocked
07004
coin mechanism sabotaged
07005
communication error coin mechanism
07006
general error coin mechanism
07101
error in cashless device
16
detection
the magnetic inlet valve is
opened 3 times within a short
period and no drink has been
selected
a NTC measures a resistance that
is higher than normal
a NTC measures a resistance that
is lower than normal
the light sensor receives not
enough pulses for too long a
time
the hot water selector cannot
find its zero position
the espresso brewer mechanism
is not reaching the desired
position
pulses from the flow meter
have not been measured for too
long a time or when both high
pressure pumps do not work
the I/O module is reporting an
error
suspected components
• leakage in the water system
• float
• machine moved without switching it
off
• temperature sensor
• wiring
• mainboard
• temperature sensor
• wiring
• mainboard
• scale inside water selector
• motor water selector
• light sensor
• wiring
• mainboard
• scale inside water selector
• water rotation disc
• brewer not mounted correct
• brewer motor defect
• wiring
• air in hoses
• high pressure pumps
• wiring
• water counter
• mainboard

Hide quick links: