• put the Sego in its final position and mark it
Step 4
• open the door
• place the drip tray with waste bin in the correct
position
• mark the location of the hole in the counter
• remove the drip tray, waste bin and the Sego to create
a free workplace
• cut out the hole in the counter
► Making a hole in your counter is your own
responsibility.
► Protect the edges of the hole from moisture
penetration.
Step 5
• place the Sego on the previously marked place
• place a large waste bin under the hole
Step 6
• enter programming, select process settings, select
waste bin counter
• select installation of 'pedestal'
• set the number of dosages to the maximum
• confirm your change