Remove The Fan Housing; Remove The Grinding Discs - BRAVILOR BONAMAT Sego Technical Manual

Hide thumbs Also See for Sego:
Table of Contents

Advertisement

2.4 Remove the fan housing

A
B
C
B

2.5 Remove the grinding discs

► Use a vacuum cleaner to remove all existing coffee beans.
► Wear gloves to protect your hands.
► Always replace both disks at the same time.
► When reassembling the machine, ensure that the grinding discs do not touch before switching on the machine.
Step 1
take out the canisters as in Step 1
Step 2
• remove the protective plate/service hatch as in
of
section 2.3
Step 2
B
D
C
E
A
F
G
H
Step 1
take out the canisters as in Step 1
Step 2
• remove the protective plate/service hatch as in
of
section 2.3
Step 3
• open the fan grid
A
• disconnect the connector through the service hatch
• remove the fan grid
• remove 2 screws from the fan housing
• remove the fan housing
of
section 2.3
Step 3
• mark the position
A
wheel
• remove 2 screws
of the bracket
B
• remove the bracket
• mark the adjusting wheel on top, for example in the
middle of the grinder outlet
known
Step 4
• remove the adjusting wheel
► Count the amount of rotations to open the grinder,
this for reassembling.
• remove the 3 screws
remove it
• remove the 3 screws
remove it
► Press and hold the drive belt slightly to hold the
grinding wheel in place, then loosen the screws.
of
section 2.3
B
C
of the bracket for the setting
and the setting wheel
C
, so that the position is
E
F
of the upper grinding disc and
G
of the lower grinding disc and
H
Step 2
D
5