2.3 Remove the fan motor

B
C
D
D
F
G
H
4
B
B
A
A
D
E
D
Step 1
• open the door and lid
• close the "yellow" slider of the canister outlets
• take all the canisters out of the machine
• remove the condense reservoir of the mixing unit
Step 2
• remove 4 screws from the protective plate
• remove the protected plate (service hatch)
► The service area can have sharp edges, wear gloves
and long sleeves.
Step 3
• open the fan grid
F
• remove the fan rotor
G
Step 4
• disconnect the connector through the service hatch
• lead the wiring with the connector through the
opening to the outside
• remove the fan motor
A
B
D
E
H
C