2.11 Remove the mainboard

2.12 Remove the (optional) interface board

2.13 Remove the inlet valve

B
A
A
10
Step 1
remove the back panel as in Step 3
Step 2
• disconnect the wiring
• remove the mainboard
A
Step 1
remove the back panel as in Step 3
Step 2
• disconnect the wiring
• remove the interface board
A
A
Step 1
remove the back panel as in Step 3
Step 2
• disconnect the wiring
• remove the 2 screws
• remove the inlet valve
• disconnect the hose
► Some water may come out of the hose.