2.14 Remove the boiler (parts)

► The boiler and their parts can be hot.

2.14.1 Reset the boiler thermostat

2.14.2 Remove the thermostat

2.14.3 Remove the temperature sensor

A
A
A
A
B
C
B
B
Step 1
remove the back panel as in Step 3
Step 2
• push both switches
A
Step 1
remove the back panel as in Step 3
Step 2
• disconnect the wiring
• remove the bolt of the thermostat
• remove the bracket
B
• remove the thermostat
Step 1
remove the back panel as in Step 3
Step 2
• disconnect the wiring from the mainboard
• remove the bolt
of the temperature sensor
A
• remove the temperature sensor
► Keep in mind that the top sensor on the boiler needs to
be attached on the top of the mainboard.
of
section 2.6
to reset
of
section 2.6
A
C
of
section 2.6
B