Electrical Installation; Special Mobil Home Requirements - Breckwell SP22 ECONOMY Series Owner's Manual

Hide thumbs Also See for SP22 ECONOMY Series:
Table of Contents

Advertisement

E. INSTALLATION IN TO A FACTORY BUILT
(METAL) FIREPLACE
(Refer to figure 20)
When installing into a factory built fireplace, the firebox
must accept the insert without modification other than
removing bolted or screwed together pieces such as
smoke shelf/deflectors, ash lips, screen or door tracks
and damper assemblies. These items must be reinstalled
to restore the fireplace to its original operating condition
if the insert is removed and not replaced. The removal of
any part must not alter the integrity of the listed fireplace
in any way. In zero-clearance fireplace installations, when
the fireplace opening is above the floor or raised hearth,
the adjustable "Breckwell SP22 Z-C Legs" can be used
to bridge the gap between the hearth and stove bottom.
Refer to figure 14.
The factory built fireplace must be listed per UL 127.
Installation must include a full height listed chimney
liner meeting type HT requirements (2100
(U.S.). The liner must be securely attached to the insert
flue collar and the chimney top. The damper area must
be sealed to prevent room air passage to chimney cavity.
Alteration of the fireplace in any manner is not permitted
except with the following exceptions:
• External trim pieces, which do not affect the operation
of the fireplace, may be removed proving they can be
stored on or within, the fireplace for re-assembly if the
insert is removed.
The fireplace damper may be removed to install the
chimney liner.
Circulating air chambers, louvers or cooling air inlet or
outlet ports (i.e. in a steel fireplace liner or metal heat
circulator) shall not be blocked.
Means must be provided for removal of the insert to clean
the chimney flue.
A permanent metal warning label must be attached to the
back wall of the fireplace opening stating the following:
"This fireplace has been altered to accommodate a
fireplace insert and should be inspected by a qualified
person prior to re-use as a conventional fireplace."
• This label is available upon request.
Final approval is contingent on the authority having
jurisdiction.
ELECTRICAL INSTALLATION
This stove is provided with a 6-foot grounded electrical
cord extending from the rear of the stove. We recom-
mend connecting to a good quality surge protector
that is plugged into a standard three-prong, 120V,
60hz electrical outlet. Voltage variations can lead to
serious performance problems. The Breckwell electri-
cal system is designed for 120V AC with no more than
5% variation. Breckwell cannot accept responsibility for
poor performance or damage due to inadequate voltage.
If connected to an older, two-prong outlet, a separate
ground wire should be run to a proper ground (refer this
to a qualified technician). Always route the electrical cord
so that it will not come in contact with any hot part of the
stove.
INSTALLATION
THE SMOKE SHELF
MAY BE REMOVED
NOTE:
THE LOG SHELF, SCREEN,
AND DOORS (IF PRESENT)
MUST BE REMOVED
F) per 1777
o
USE THE ZERO-CLEARANCE
SKIRT TO SUPPORT THE
INSERT ON RAISED FIREPLACES
SPECIAL MOBILE HOME REQUIREMENTS
WARNING: DO NOT INSTALL IN A SLEEPING ROOM.
NOTE: Installation should be in accordance with the Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24
For installation in a mobile home, an outside source of combustion air must be used
(see "COMBUSTION AIR SUPPLY").
The SP22 must be grounded to the steel chassis of the home with 8 Ga. copper wire
using a serrated or star washer to penetrate paint or protective coating to ensure
grounding.
The SP22 must be securely fastened to the floor of the mobile home through the two
holes in the rear of the stove using 2, ¼" lag bolts that are long enough to go through
both a hearth pad, if used, and the floor of the home. (See figure 21)
Refer to "VENTING" for proper exhaust configurations.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL
AND CEILING/ROOF MUST BE MAINTAINED.
VERTICAL CAP
STORM COLLAR
12"
THE MASONRY LINING
THE METAL SIDES, FRAME MEMBERS, OR OTHER
MAY NOT BE REMOVED
STRUCTURAL COMPONENTS OF THE FACTORY BUILT
FIREPLACE MAY NOT BE REMOVED OR ALTERED
FIGURE 20
B
SECURE PEDESTAL TO FLOOR
WITH 2, 1/4" x 2" LONG
LAG BOLTS.
FIGURE 21
13
COVER PLATE
(NON-COMBUSTIBLE)
SEAL WITH SILICONE.
3 OR 4 INCH L-VENT
OR STAINLESS STEEL
FLEXIBLE OR SINGLE
WALL PIPE
THE DAMPER MAY
BE REMOVED
INTERNAL BAFFLES
MAY BE REMOVED
TO PREVENT FIREPLACE
ODORS FROM ENTERING
THE HOME, PAINT THE
INTERIOR OF THE FIREPLACE
WITH LATEX PAINT
A
DRILL 2, 5/16" HOLES
IN PEDESTAL BASE.